User`s guide
Chapter 5 _________________________________________________________________ Operation 
Example 2 
In this example the analog output 1 is set to send measurement 
data as a current signal, the gain is set to 1 mA/m/s and the offset 
to 4 mA. 
S aout1_o,0.004 
S aout1_g,0.001 
S aout1mode,0 
Example 3 
In this example both analog outputs are disabled to reduce power 
consumption. 
S aout1mode,3 
S aout2mode,7 
G — Get Parameter 
The G command shows the values of the configuration 
parameters. You can either display all parameter values or only 
certain values.  
For a list of available parameters, see Appendix D Configuration 
Parameters on page 205. 
Get All Parameters 
You can use the G command to view all parameter values if you 
do not specify any parameters in the command. 
G 
Get Specified Parameters 
You can use the G command to view specified parameter values.  
G x 
where 
x 
= 
Any parameter in Appendix D Configuration Parameters on 
page 205 
VAISALA _______________________________________________________________________ 113 