User`s guide
Chapter 5 _________________________________________________________________ Operation 
Table 35  List of Configuration Mode Commands 
Command  
Description 
? 
Displays a list of configuration commands. 
BAUD 
Changes or displays serial port settings. 
CLEARERR 
Resets error counters. 
CLOSE 
Switches the serial port to measurement mode. 
ERRORS 
Fetches the error codes and counter information from WMT700. 
G 
Displays either all or specified parameters. 
H 
Displays a list of data messages and available values for 
measurement unit, profile, baud rate, interface, and analog 
output mode. 
MEAS 
Starts wind measurement based on the user-configurable 
averaging time. WMT700 does not send data messages 
automatically. 
POLL  
Tests data polling. 
RESET 
Resets WMT700. 
S 
Changes selected parameters or defines new data messages. 
START 
Starts continuous measurement. 
STOP 
Stops continuous measurement. 
VERSION 
Displays the software version. 
WIND_GET 
Fetches wind calibration information. 
Parameter Handling Commands 
All the commands in the configurating mode are in the following 
form: 
>CMD x,y<enter> 
|  |  | | | | |___ Press Enter key to activate the command 
| | | | | |_______Value of the parameter 
|  | | | |_______ Comma  
| | | |________ Any parameter in Table 66 on page 205 
|  | |__________ Space 
|  |______________ Command 
|_________________ Configuration mode prompt 
The parameter name and allowed parameter values depend on the 
command. For certain commands they are optional. In the 
following command descriptions, WMT700 configuration mode 
prompt and enter are left out for clarity. 
VAISALA _______________________________________________________________________ 111 