Mains Power Supply WHP25 USER'S GUIDE M210376en-A December 2002
PUBLISHED BY Vaisala Oyj P.O. Box 26 FIN-00421 Helsinki Finland Phone (int.):+358 9 8949 1 Fax: +358 9 8949 2227 Visit our Internet pages at http://www.vaisala.com/ © Vaisala 2002 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice.
___________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION .......................................................3 About This Manual..................................................3 Contents of This Manual.......................................3 Version Information...............................................4 Feedback..............................................................4 Safety .........................................................
User's Guide ________________________________________________________ List of Figures Figure 1 Figure 2 WHP25 Mains Power Supply ................................... 8 Mounting WHP25 Mains Power Supply on a Pole Mast ............................................................ 10 Figure 3 Location of the WHP25 Jumpers............................ 11 Figure 4 Instructions Label for the WHP25 Jumper Settings and Wiring ................................................ 11 Figure 5 WHP25 Connectors and Glands ..
Chapter 1 ___________________________________________ General Information CHAPTER 1 GENERAL INFORMATION This chapter provides general notes for the product. About This Manual This manual provides information for installing, operating, and maintaining WHP25 Mains Power Supply. Contents of This Manual This manual consists of the following chapters: - Chapter 1, General Information, provides general notes for the product. - Chapter 2, Product Overview, introduces the WHP25 Mains Power Supply features.
User's Guide ________________________________________________________ Version Information Table 1 Manual Revisions Manual Code T647en-1.1 U146en-1.1 M210376en-A Description WHP25 Power Supply Technical Reference WHP25 Power Supply Quick Reference Guide This manual, the first version of the WHP25 Mains Power Supply User's Guide. Replaces the above mentioned Technical Reference and Quick Reference Guide.
Chapter 1 ___________________________________________ General Information CAUTION Caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product could be damaged or important data could be lost. NOTE Note highlights important information on using the product. Product Related Safety Precautions WHP25 Mains Power Supply delivered to you has been tested for safety and approved as shipped from the factory.
User's Guide ________________________________________________________ - Handle ESD sensitive components on a properly grounded and protected ESD workbench. When this is not possible, ground yourself to the equipment chassis before touching the boards. Ground yourself with a wrist strap and a resistive connection cord. When neither of the above is possible, touch a conductive part of the equipment chassis with your other hand before touching the boards.
Chapter 2 ____________________________________________ Product Overview CHAPTER 2 PRODUCT OVERVIEW This chapter introduces the WHP25 Mains Power Supply features. Introduction to WHP25 Mains Power Supply WHP25 is a compact AC (Mains) Power Supply Unit intended for outdoor use. The unit is capable of delivering power, for example, to the WA25 Wind Set. The nominal input power of 230 VAC can be changed by jumpers between 100 VAC and 245 VAC (±10 %). The WHP25 unit provides two power outputs, namely 24.
User's Guide ________________________________________________________ 0212-184 Figure 1 WHP25 Mains Power Supply The following numbers refer to Figure 1 above: 1 2 3 = Gland for AC (mains) input cable = Gland for optional power output cable = Gland for power output cable 8 ______________________________________________________ M210376en-A
Chapter 3 __________________________________________________ Installation CHAPTER 3 INSTALLATION This chapter provides you with information that is intended to help you install WHP25 Mains Power Supply. Installation Procedure Before installation, route the input (AC) power cable near the mast, which WHP25 Mains Power Supply will be mounted to. Make sure you selected a pole mast with a diameter from 99 to 105 mm for installation with the standard mounting clamp.
User's Guide ________________________________________________________ 0212-185 Figure 2 Mounting WHP25 Mains Power Supply on a Pole Mast The following numbers refer to Figure 2 above. 1 2 3 4 5 6 3. = Enclosure = Slot screw M6, washer A6, spring washer B6, and nut M6 = Mounting clamp = Pole mast, diameter from 99 to 105 mm = Cable gland = Cable If the local voltage level is other than 230 VAC, reselect the voltage with the X2 and X3 jumpers located inside the WHP25 unit.
Chapter 3 __________________________________________________ Installation 0212-186 Figure 3 Location of the WHP25 Jumpers The following numbers refer to Figure 3 above. 1 2 3 = Plastic shield above the jumpers = Caution label = Fixing screw for the plastic shield F1 X1 2AT FUSES Primary 8AT Secondary F2 X4 1 2 3 4 5 6 7 8 (X2, X3) MAINS VOLTAGE 100V 115V 200V 215V Factory setting 230V 245V X2 38VAC 0.9A E L N X3 Figure 4 ACout DCout (RG13H) (WA25) NOTE! MAINS INPUT 1.0 - 2.
User's Guide ________________________________________________________ connector. To ease the wire connection the connector has spring loaded terminals. 6. Connect the ground wire to the crimp assembled under the screw. The wiring of the AC (mains) input to the X1 connector is instructed in Figure 4 on page 11. Refer to Figure 5 below for the location of the connectors and cable glands on the WHP25 unit. 7. Tighten the input cable glands.
Chapter 3 __________________________________________________ Installation 8. CAUTION Enter the output power cable(s) through the rightmost cable gland(s). For better protection against RF interference, ground the cable as shown in Figure 6 below. Push the shield through the two washers (number 3 in Figure 6 below) and squeeze part of it evenly between them. The shield mesh must not touch the circuit board or its components. Make sure no pieces of the mesh or other metal parts touch the circuit board.
User's Guide ________________________________________________________ Installation Examples Installation with WAC151 and WA25 Wind Set Figure 7 below illustrates a typical installation with WA25 Wind Set. As a power source, it is recommended to use WHP25 Mains Power Supply, with a mast mountable, allweather enclosure. For the wiring instructions, refer to Figure 8 on page 15.
Chapter 3 __________________________________________________ Installation 0212-190 Figure 8 Wiring WAC151 with WHP25 Mains Power Supply and WA25 Wind Set VAISALA__________________________________________________________15
User's Guide ________________________________________________________ NOTE Total wire resistance of less than 0.3 Ω is recommended for WA25 Wind Set. Figure 8 on page 15 provides the wiring diagram for WA25 Wind Set mounted to WAC151 Cross Arm. When using the standard power and signal cables ZZ45049 and ZZ45048, the connections are the following: 1. For power supply, connect the YEL, GRN, and PNK colored wires to the screw terminal #2 and the WHT, BRN, and GRY colored wires to the terminal #3. 2.
Chapter 3 __________________________________________________ Installation 0206-056 Figure 9 Wiring WAT12 with WHP25 Mains Power Supply and WA25 Wind Set VAISALA__________________________________________________________17
User's Guide ________________________________________________________ This page intentionally left blank.
Chapter 4 ______________________________________________ Troubleshooting CHAPTER 4 TROUBLESHOOTING This chapter describes common problems, their probable causes and remedies, and contact information. Common Problems Table 2 below lists some common problems and their remedies. Table 2 Some Common Problems and their Remedies Problem Probable Cause No voltage between Fuse F1 is broken. X5 and the grounding crimp. No voltage from the Fuse F2 is broken 24 VDC output. No voltage from the Fuse R3 is broken.
User's Guide ________________________________________________________ Replacing Fuses Follow the procedure below to replace a broken fuse: 1. Remove the four screws attaching the cover of the WHP25 unit. Remove the cover. 2. Disconnect the power input. 3. Refer to Figure 10 below for the location of the replaceable fuses. 4. Open the holder of the broken fuse (either F1 or F2) with a screw driver. 5. Replace the broken fuse (either F1 or F2) with a new one and screw the holder back onto its place.
Chapter 4 ______________________________________________ Troubleshooting Technical Support For technical questions or for comments on the manuals, contact the Vaisala technical support: E-mail helpdesk@vaisala.
User's Guide ________________________________________________________ Return Instructions If the product needs repair, please follow the instructions below to speed up the process and avoid extra costs. 1. Read the warranty information. 2. Write a Problem Report with the name and contact information of a technically competent person who can provide further information on the problem. 3.
Chapter 5 _______________________________________________Technical Data CHAPTER 5 TECHNICAL DATA This chapter provides the technical data for WHP25 Mains Power Supply. Specifications Table 3 WHP25 Mains Power Supply Specifications Property Input operating power: Nominal Optional selections DC output (X4/4, 5 - 6, 7) AC output (X4/1 - 2) Fuses: Primary 24 V output 38 V output Cable glands (3) Description/Value 230 VAC ±10 %, 50/60 Hz, 1.0 A max. 100/115/200/215/245 VAC (±10 %) 24.0 ±2.5 VDC, 5.
User's Guide ________________________________________________________ Property Mounting clamp material Ingress protection Unit dimensions Mounting Weight Description/Value AlMgSi, gray anodized IP65 (Nema 4) 220 (w) × 120 (h) × 81 (d) mm (cable glands add 23 mm to height) To a ∅ 99 ... 105 mm pole mast tube with standard mounting clamp 3.