User Manual

Chapter 5 __________________________________________ Configuring TCP/IP-Based Telemetry
VAISALA______________________________________________________________________ 269
Passive connection/Accept
incoming
Allow incoming connection requests. If selected, the QML logger opens
a server socket in the port
specified by the Local port
number parameter.
Active connection None = no active connection; Auto
start = connect to remote server at
startup and try to keep connection
open all the time; With any
character = connect to remote
server when data is being sent to
port.
Flush input buffer Defines the connection event which
causes any data present in the input
buffer to be discarded.
Flush output buffer Defines the connection event which
causes any data present in the
output buffer to be discarded.
First remote access point Always use the first defined remote
server when opening an active
connection.
Debug/Output component Port to which debug output will be
written. No selection disables debug
output.
Debug/Telnet protocol
debug
Output debug information for Telnet
protocol. Used only if the debug
output component is selected.
Buffers/Transmit [bytes] Size of the transmit buffer in bytes.
Configure hosts Opens the remote host configuration
dialog. For instructions, see section
Remote Host Configuration on page
270.
Table 49 Virtual COM Port Parameters (Continued)