User Manual
User's Guide ______________________________________________________________________
126 _________________________________________________________________ M210933EN-C
The available data by message type is as follows:
Vaisala All-Weather Precipitation Gauge VRG101
The default communication parameters for the precipitation gauge are
as follows:
Lizard Variable Message Description
mwv_hdr MWV(QUERY) MWV message header
dir MWV(QUERY) Wind direction [deg]
ref MWV(QUERY) Reference. R = relative, T = true
spd MWV(QUERY) Wind speed
uni MWV(QUERY) Wind speed unit.
K = km/h, M = m/s, N = kt
mwv_sta MWV(QUERY) MWV status field and checksum
orig_WT50_mwv MWV(QUERY) Original receive string
ta_typ XDR_TU Transducer type: C for Ta
ta XDR_TU Air temperature
ta_uni XDR_TU Ta. unit: C for ÂșC
ta_id XDR_TU Transducer ID for Ta
rh_typ XDR_TU Transducer type: H for RH
rh XDR_TU Relative humidity
rh_uni XDR_TU RH unit: P for %
xdr_sta XDR_TU Misc. XDR status
orig_WT50_xdr XDR_TU Original receive string
Parameter Value
Speed 9600 bps
Parity none
Data bits 8
Stop bits 1
Handshake none