User Manual

User’s Guide ______________________________________________________________________
136 __________________________________________________________________M210785EN-E
Table 17 Logged Data
Col # Column Label Content
1Group
Log group
1
2 Interval [s]
Logging interval in seconds
1
4 Source Source for the logged variable
3 kBytes/day
Log memory consumption per day
1, 2
5 Variable Name of the logged variable
1. The column contains redundant data which is hidden, that is, data is shown
only once in each log group.
2. When the log group contains non-numeric data, such as text or binary
arrays, it is not possible to estimate memory consumption. In such cases
the column will show 0 (null).
Table 18 Reported Data
Col # Column Label Content
1 Report Report name
2 Interval [s] Report creation interval in seconds. Note that
this is not necessarily the same as the
transmission interval, as the report may be
polled
3 Source Source for the reported variable
4 Variable Name of the reported variable
Table 19 Report Communications
Col # Column Label Content
1Port
Destination port
1
2 Comms. Type Communications type, such as Serial line
report send, or the communications device
type, such as PSTN-Modem
1
3 Report Name of the sent report
4 Poll Command Poll command if the report is polled. If a
communications device is attached to the port,
this information is not available
5 Header Report header string
6 Footer Report footer string
1. The column contains redundant data which is hidden, that is, data is shown
only once in each log group.