humidity / dew point / moisture in oil / carbon dioxide / pressure / wEATHER
HVAC LUBRICATION POWER GENERATION compressed air building automation LIFE SCIENCE AccuRate instruments HIGH-TECH CLEANROOMS CHAMBERS reliable measurements services www.vaisala.
We at Vaisala have always valued the opportunity to push ourselves and our products to a higher level for the benefit of our customers. Our new strategy nurtures this opportunity, allowing us to focus on customers who operate in tightly controlled and demanding areas in the chosen industrial applications introduced in this catalog. We are confident that concentrating Vaisala's product and business development efforts on these areas will result in the overall success of our customers.
Table of Contents by Parameters Humidity HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement 4 HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications 8 HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces 9 HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications 10 HMT335 Humidity and Temperature Transmitter for High Temperatures 11 HMT337 Humidity and Temperature Transmitter for High Hu
Moisture in Oil MMT330 Moisture and Temperature Transmitter Series for Oil 88 MMT310 Series Moisture and Temperature Transmitter for Oil 94 MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications 96 MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil 98 Carbon Dioxide GMP343 Carbon Dioxide Probe for Demanding Measurements 100 GMT220 Series Carbon Dioxide Transmitters for Industrial Applications 102 GMM220 Carbon Dioxide Modules for Demanding OEM Applica
Humidity www.vaisala.com HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement Features/Benefits The HMT330 transmitter family has the solution for demanding industrial humidity measurements. The Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 is designed for demanding industrial applications where stable measurement and wide customization is important.
Graphical Display of History and Measurement Trends The HMT330 can be ordered with a large numerical and graphical display, which allows the user to clearly monitor operational data, measurement trends and 1-year measurement history. The optional data logger with real-time clock makes it possible to generate over four years of measured history, and zoom in on any desired time or time frame. The battery backup of the clock guarantees a reliable logging of measured data.
Technical Data Performance Inputs and Outputs Relative humidity Operating voltage 10 ... 35 VDC, 24 VAC with optional power supply module 100 ... 240 VAC, 50/60 HZ Power consumption at +20 °C (Uin 24 VDC) RS-232 max. 25 mA max. 25 mA Uout 2 x 0 ... 1 V/0 ... 5 V/0 ... 10 V max. 60 mA Iout 2 x 0 ... 20 mA display and backlight + 20 mA during chemical purge max. 110 mA during probe heating (HMT337) + 120 mA Analog outputs (2 standard, 3rd optional) current output 0 ... 20 mA, 4 ... 20 mA voltage output 0..
Mechanics Dimensions Cable bushing Dimensions in mm (inches) M20 x 1.5 for cable diameter 8 ... 11 mm/0.31 ... 0.43" Conduit fitting 1/2" NPT User cable connector (optional) M12 series 8-pin (male) option 1 female plug with 5 m (16.4 ft) black cable option 2 female plug with screw terminals Probe cable diameter HMT333 (+80 °C) 6.0 mm other probes 5.5 mm Housing material G-AlSi 10 Mg (DIN1725) Housing classification IP 65 (NEMA4) Transmitter with WLAN antenna 183 (7.20) same as measurement range -40 ..
HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted Applications HMT331 Humidity and Temperature Transmitter with short flexible probe and optional WLAN. The HMT331 is the state-of-the-art wall-mount humidity instrument. Features/Benefits ▪ For temperatures -40 ... +60 °C (-40 ... +140 °F) ▪ Application examples: cleanrooms, pharmaceutical processes, greenhouses, swimming halls, museums and archives Technical Data Temperature measurement range -40 ... +60 °C (-40 ...
HMT333 Humidity and Temperature Transmitter for Ducts and Tight Spaces 210697 duct installation kit for HMT333 and HMT337. For outdoor environments, the DTR502B solar radiation shield provides protection for the probe. The shield can be installed on a pole, a beam or a flat surface. The HMT333 transmitter has a small probe for remote applications. Features/Benefits For remote probe installations in demanding HVAC applications ▪ For temperatures -40 ... +80 °C (-40 ... +176 °F) or -40 ... +120 °C (-40 .
HMT334 Humidity and Temperature Transmitter for High Pressure and Vacuum Applications The display shows measurement trends and over four-year real time measurement history. The HMT334 is ideal for permanent installations into pressurized or vacuum processes. Features/Benefits ▪ For pressures up to 100 bar and vacuum applications ▪ For temperatures -70 ... +180 °C (-94 ...
HMT335 Humidity and Temperature Transmitter for High Temperatures The installation flange allows an adjustable installation depth for the probe. The HMT335 has a robust stainless steel probe ideal for high flow rates in hot processes. Features/Benefits ▪ For temperatures -70 ... +180 °C (-94 ... +356 °F) ▪ ▪ Long metal probe head ▪ ▪ Adjustable installation depth Robust Probe Ideal for High Flow Rates Application example: hot drying processes Technical Data Temperature measurement range -70 ...
HMT337 Humidity and Temperature Transmitter for High Humidity Applications Duct installation kit Features/Benefits The HMT337 is the ideal transmitter for the most demanding process and meteorological measurements. Technical Data Temperature measurement range -70 ... +180 °C (-94 ...
HMT338 Humidity and Temperature Transmitter for Pressurized Pipelines down to the appropriate depth. The hex nut is tightened with a wrench to lock the probe in its place. Hot tapping is possible in pressures up to 10 bar. Graphical Display of History and Measurement Trends From the display, the user can easily monitor operational data, measurement trends and one-year measurement history.
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration can also easily be made in the field.
Interchangeable Probes for HMT360 Intrinsically Safe Humidity and Temperature Transmitter Dimensions Technical Data Dimensions in mm (inches) HMP361 for wall mounting Probe diameter 12 mm 62 (2.44) -40 ... +60 °C (-40 ... +140 °F) ø12 (o.47) Temperature range 41 (1.61) 86 (3.39) 127 (5) The HMP361 probe in this picture has a stainless steel netting filter. Dimensions Technical Data HMP363 for confined spaces Dimensions in mm (inches) -40 ... +120 °C (-40 ... +248 °F) rubber cable -40 ...
Dimensions HMP365 for high temperature Temperature range Probe cable length -40 ... +180 °C (-40 ... +356 °F) Dimensions in mm (inches) 41 (1.6) 2, 5 or 10 meters Probe diameter ø13.5 (0.53) Technical Data 51 (2.0) 192 (7.56) 13.5 mm 253 (9.96) Installation The HMP365 probe is designed for high temperature environments. 75 (2.96) 50 (1.97) Mounting flange 210696 Cable Gland M20x1.5 with splitting seal Installation flange: stainless steel HMP247CG drilling 16...22 (0.63...0.
Technical Data Performance Operating Environment Relative humidity Temperature range operating temp. range for electronics with display storage Pressure range Measurement range 0 ... 100 %RH Accuracy (including non-linearity, hysteresis, and repeatability) for typical applications with Vaisala HUMICAP® 180 or 180R at +15 ... +25 °C (59 ... +77 °F) ± 1.0 %RH (0 ... 90 %RH) at -20 ... +40 °C (-4 ... +104 °F) at -40 ... +180 °C (-40 ... +356 °F) ±1.7 %RH (90 ... 100 %RH) ±(1.0 + 0.008 x reading) %RH ± (1.
Classification with Current Outputs Dimensions Europe / VTT Dimensions in mm (inches) Safety factors II 1 G Ex ia IIC T4 Ga VTT 09 ATEX 028 X issue No: 1 Ui = 28 V, Ii = 100 mA, Pi = 700 mW Ci = 1 nF, Li negligibly low Environmental specifications -40 ... +60 °C (-40 ... +140 °F) Tamb 0.8 ... 1.
Accessories HMT361 Accessory Ball valve ISO 1/2 with welding joint Cable Gland M20 x 1.5 with splitting seal Duct installation kit Fitting body ISO1/2 solid structure Fitting body M22 x 1.5 Fitting body NPT1/2 Fitting body NPT1/2 solid structure Mounting flange Swagelok for 12mm probe, 1/2" NPT thread Swagelok for 12mm probe, 3/8" ISO thread part number BALLVALVE-1 HMP247CG 210697 DRW212076SP 17223 17225 NPTFITBODASP 210696 SWG12NPT12 SWG12ISO38 For more information, visit www.vaisala.
www.vaisala.com HMT310 Humidity and Temperature Transmitter The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT310 models (from left to right): HMT313, HMT317, HMT314, HMT318, HMT315 and HMT311. Features/Benefits ▪ Next-generation Vaisala HUMICAP® Sensor for excellent accuracy and stability ▪ Full 0 ...
Technical Data Measured Values Electrical Connections typical applications applications with chemical purge and/or warmed probe Accuracy (incl. non-linearity, hysteresis and repeatability) at a temperature range of +15 ... +25 °C ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) -20 ... +40 °C ±(1.0 + 0.008 x reading) %RH -40 ... +180 °C ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty ±0.6 %RH (0 ... 40 %RH)* (+20 °C) ±1.0 %RH (40 ... 97 %RH)* Two analog outputs, 0 ... 20 mA or 4 ...
www.vaisala.com Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 Features/Benefits The HMT120/130 with and without a display. The Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 are designed for humidity and temperature monitoring in cleanrooms and are also suitable for demanding HVAC and light industrial applications. Performance The HMT120/130 incorporates Vaisala HUMICAP® technology that measures relative humidity accurately and reliably.
Technical Data Performance Mechanics RELATIVE HUMIDITY Material transmitter housing display window probe body probe grid filter Housing classification Connections inputs and outputs probe interface Probe cable lengths Display (optional) Measurement range 0 ... 100 %RH Accuracy including non-linearity, hysteresis, and repeatability temperature range 0 °C ... +40 °C 0 ... 90 %RH ±1.7 %RH 90 ... 100 %RH ±2.5 %RH temperature range -40 ... 0 °C, +40 ... +80 °C 0 ... 90 %RH ±3.0 %RH 90 ... 100 %RH ±4.
www.vaisala.com HMW60/70 Humidity and Temperature Transmitters for Wall Mounting in HVAC Applications Vaisala HUMICAP® Humidity and Temperature Transmitters HMW60 and HMW70 are designed for use in air conditioning applications where accurate and stable control of relative humidity and temperature are required. Features/Benefits ▪ ▪ Accuracy up to ±2 %RH ▪ Selectable signal output of 0 ... 1 V, 0 ... 5 V or 0 ...
Technical Data 60 Series: 2-wire, 4 to 20 mA output Wall mount General - 60 Series RH only RH & T T only HMW60U HMW60Y HMW60T Supply voltage 10 ... 35 VDC (RL = 0 ohm) 20 ... 35 VDC (RL = 500 ohm) 4 ... 20 mA Output signal 70 Series: 3-wire, variable voltage output General - 70 Series Wall mount Supply voltage range depends on the selected output signal DC AC 0 ... 1V 10 ... 35 V 9 ... 24 V 0 ... 5 V 14 ... 35 V 12 ... 24 V 0 ... 10 V 19 ... 35 V 16 ...
www.vaisala.com HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC Applications Features/Benefits Vaisala HUMICAP Humidity and Temperature Transmitters HMD60 and HMD70 are designed for use in air conditioning applications where accurate and stable control of relative humidity and temperature are required.
Technical Data 60 Series: 2-wire, 4 to 20 mA Output Duct mount General - 60 Series RH only RH & T T only HMD60U HMD60Y HMD60T Supply voltage 10 ... 35 VDC (RL = 0 ohm) 20 ... 35 VDC (RL = 500 ohm) 4 ... 20 mA Output signal 70 Series: 3-wire, Variable Voltage Output General - 70 Series Duct mount Supply voltage range depends on the selected output signal DC AC 0 ... 1V 10 ... 35 V 9 ... 24 V 0 ... 5 V 14 ... 35 V 12 ... 24 V 0 ... 10 V 19 ... 35 V 16 ...
www.vaisala.com Vaisala INTERCAP® Humidity and Temperature Transmitter Series HMW80 The HMW80 combines excellent stability with easy installation and reliable operation. Features/Benefits ▪ Cost-efficient, dependable solution for humidity and temperature measurement for heating and ventilation ▪ Measurement range 0 ... 100 %RH and -5 ...
Technical Data Performance Inputs and outputs Relative humidity HMW82, TMW82 Measurement range Accuracy Temperature range 30 ... 70 %RH 0 ... 30 %RH, 70 ... 100 %RH Temperature range 0 ... 100 %RH Stability Humidity sensor 0 ... 100 %RH 10 ... 30 °C ±3 %RH ±5 %RH -5 ... +10 °C, +30 ... + 55 °C ±7 %RH ±3 %RH / 5 years Vaisala Intercap® Temperature Measurement range Accuracy +10 ... +30 °C -5 ... +10 °C, +30 ... +55 °C Temperature sensor -5 ... +55 °C ±0.5 °C ±1.
www.vaisala.com HMD42/53 Humidity and Temperature Transmitters for Ducts in Commercial HVAC Applications Features/Benefits ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ The duct mounted Vaisala INTERCAP® Humidity and Temperature Transmitters HMD42 and HMD53 are designed for building automation applications. They combine reliable operation with excellent stability, providing low cost of ownership to the user.
Technical Data Relative Humidity General Measurement range Typical accuracy Temperature range 0 ... 90 %RH 90 ... 100 %RH Temperature range 0 ... 100 %RH 0 ... +40 °C (+32 ... +104 °F) ±3 %RH ±5 %RH -20 ... 0 °C, +40 ... +60 °C (-4 ... +32 °F, +104 ... +140 °F) 0 ... 90 %RH ±5 %RH 90 ... 100 %RH ±7 %RH Humidity sensor Vaisala INTERCAP® Stability ±2 %RH / 2 years Response time at 20 °C (+68 °F), 90 % response 15 s Temperature Measurement range Output scale Accuracy 0 ... +40 °C (+32 ... +104 °F) -20 ...
www.vaisala.com HMM210 Series Humidity Modules for Environmental Chambers relative humidity and temperature or dewpoint measurement with various configurations. All modules have microprocessor based electronics and are equipped with analog or digital outputs. Unique Warmed Probe The warmed probe and composite sensor, available on the dewpoint probe configuration, is warmed to always remain a few degrees higher than ambient.
Technical Data Relative Humidity General Measurement range Accuracy (including non-linearity, hysteresis and repeatability) 0 ... 100 %RH Operating temperature range Probe -70 ... +180 °C (-94 ... +356 °F) Electronics -5 ... +55 °C (+23 ... +131 °F) Storage temperature range (Electronics) -40 ... +70 °C (-40 ... +158 °F) Sensor protection (standard) stainless steel sintered filter Connections screw terminals for 0.5 ... 1.5 mm2 wires +2 %RH (0 ... 90 %RH) +3 %RH (90 ...
www.vaisala.com HMM100 Humidity Module for Environmental Chambers The Vaisala HUMICAP® Humidity Module HMM100. Features/Benefits The HMM100 ▪ Full temperature compensation over the operating temperature range of -70˚C ... +180˚C ▪ High temperature tolerance, also suitable for heatsterilization The Vaisala HUMICAP® Humidity Module HMM100 is an open frame module for integration into environmental chambers. The modules provide a single analog output channel for relative humidity (RH) or dewpoint (Td).
Technical Data Performance Mechanics relative humidity Service cable connector Probe diameter Probe cable lengths Probe material plastics stainless steel Probe mounting clamp Mounting bracket material lid bottom plate Module housing material Measurement range 0 ... 100 %RH Accuracy (incl. non-linearity, hysteresis and repeatability) temperature range -20 ... +40 °C 0 ... 90 %RH ±2 %RH 90 ... 100 %RH ±3 %RH temperature range -40 ... -20 °C, +40 ... +180 °C 0 ... 90 %RH ±2.5 %RH 90 ... 100 %RH ±3.
www.vaisala.com Vaisala INTERCAP® Humidity and Temperature Probe HMP60 The HMP60 for extreme conditions. Features/Benefits HMP60 Several Outputs ▪ ▪ ▪ Miniature-size humidity probe There are two configurable voltage outputs with relative humidity, temperature or dew point scaling. Four voltage output ranges are available. ▪ Cable detachable with standard M8 connector The HMP60 is a simple, durable and cost-effective humidity probe.
Technical Data Operating Environment Measurement range Typical accuracy temperature range 0 ... 90 %RH 90 ... 100 %RH temperature range 0 ... 90 %RH 90 ... 100 %RH Humidity sensor 0 ... 100 %RH 0 ... +40 °C ±3 %RH ±5 %RH -40 ... 0 °C, +40 ... +60 °C ±5 %RH ±7 %RH Vaisala INTERCAP® TEMPERature Measurement range Accuracy over temperature range -40 ... +60 °C -40 ... +60 °C ±0.6 °C DEW POINT Measurement range -40 ... +60 °C Typical accuracy temperature range 0 ...
www.vaisala.com Vaisala HUMICAP® Humidity and Temperature Probe HMP110 The HMP110 with excellent stability and high chemical tolerance. Features/Benefits HMP110 Several Outputs ▪ Miniature-size humidity transmitter ▪ Low power consumption and fast startup for battery powered applications The temperature measurement is a standard feature, dew point measurement is optional. Three standard voltage outputs are available. ▪ Measurement range: 0 ... 100 %RH; -40 ...
Technical Data Performance TEMPERature Measurement range -40 ... +80 °C Accuracy over temperature range 0 ... +40 °C, ±0.2 °C -40 ... 0 °C, +40 ... +80 °C ±0.4 °C Temperature sensor Pt1000 RTD 1/3, Class B IEC 751 DEW POINT Measurement range -40 ... +80 °C Accuracy (incl. non-linearity, hysteresis and repeatability) temperature range 0 ... +40 °C when dew point depression < 15 °C ±1 °C when dew point depression 15 ... 25 °C ±2 °C temperature range -40 ... 0 °C, +40 ...
www.vaisala.com HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking Applications The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 is a highperformance, portable humidity reference that is exciting to use.
Technical Data HMP75, HMP76 and HMP77 Probes Measured Variables MI70 Measurement Indicator Indicator General Relative humidity Menu languages Measurement range 0 ... 100 %RH Accuracy (including nonlinearity, hysteresis and repeatability) at +15 ... +25 °C (+59 ... +77 °F) ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) at -20 ... +40 °C (-4 ... +104 °F) ±(1.0 + 0.008 x reading) %RH at -40 ... +180 °C (-40 ... +356 °F) ±(1.5 + 0.015 x reading) %RH Factory calibration ±0.6 %RH (0 ...
www.vaisala.com HMI41 Indicator and HMP42/HMP46 Probes The Vaisala HUMICAP® Humidity Indicator HMI41 fitted with the Vaisala HUMICAP® Humidity and Temperature Probes HMP42 or HMP46 can be used for spot checking and field calibration applications. In addition to displaying the humidity and temperature readings, the HMI41 indicator calculates dew point and wet bulb temperature, absolute humidity and mixing ratio. The indicator has an easy-to-read two line liquid crystal display.
Technical Data HMI41 Indicator Calculated variables HMP46 Probe dew point temperature, absolute humidity, wet bulb temperature, mixing ratio 0.1 %RH; 0.1 °C/°F 4 batteries, type AA (LR 6) Resolution Power supply Battery operation time (alkaline batteries) 72 h continuous use Auto-off function Operating temperature -20 ... +60 °C (-4 ... +140 °F) Storage temperature -40 ... +70 °C (-40 ...
Technical Data General for Probes Dimensions Cable length 1500 mm; extended spiral cable Operating temperature range for electronics -20 ... +60 °C (-4 ...
Reliable and Cost-efficient HVAC Products / HUMIDITY & CO2 When performance can’t be compromised, choose Vaisala for humidity and CO2 measurement solutions. Check out NEW products: www.vaisala.com/HVAC www.vaisala.
www.vaisala.com HM34 Pocket Size Relative Humidity Meter The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM34 provides a fast and convenient way to accurately spot-check relative humidity and temperature. Fast and Easy-to-Use In measurement mode, the extendable probe just slides out. Normally, measurement takes only a few seconds. The HM34 meter includes a HOLD button which allows the user to retain an RH or T measurement until it has been noted or recorded.
Technical Data Relative Humidity General Measurement range Accuracy Display Hold function Power supply Battery operation time Automatic POWER OFF 0 ... 100 %RH ±2% (0 ... 90 %RH) ±3% (90 ... 100 %RH) Resolution 0.1 %RH Temperature dependence ±0.04 %RH/°C Sensor type HUMICAP®H thin film capacitive sensor Response time (90%) 15 s with membrane filter 5 s with plastic grid Temperature Range Accuracy Resolution Temperature dependence Sensor -20 ... +60 °C (-4 ... +140 °F) ±0.3 °C (±0.54 °F) 0.1 °C (0.
www.vaisala.com HMK15 Humidity Calibrator accepted and reliable method to calibrate humidity instruments. Usually two or three different salt solutions are used. Salts are chosen according to the application. three step plugs to fit all chamber holes (12 mm, 13.5 mm and 18.5 mm) transit covers for secure transportation and long-term storage Certified Salts The HMK15 can be ordered with certified and pre-measured salts.
Technical Data General Options The standard HMK15 consists of the following parts: Certified and ready dosed salts: Order code: Total uncertainty*: LiCl salt 11 %RH 33 %RH MgCl2 salt NaCl salt 75 %RH 97 %RH K2SO4 salt *Uncertainties given at +20 °C 19729HM 19730HM 19731HM 19732HM (±1.3 %RH) (±1.2 %RH) (±1.5 %RH) (±2.
www.vaisala.com HMP155 Humidity and Temperature Probe Features/Benefits HMP155 with an additional temperature probe and optional Stevenson screen installation kit. New Probe for Reliability The new Vaisala HUMICAP Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. ® Long-term Stability The HMP155 has a new generation Vaisala HUMICAP®180R sensor that has excellent stability and withstands well harsh environments.
Technical Data General Performance Relative humidity Measurement range Accuracy (incl. non-linearity, hysteresis and repeatability) at +15 ... +25 °C (+59 ... +77 °F) 0 ... 100 %RH ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) -20 ... +40 °C (-4 ... 104 °F) ±(1.0 + 0.008 x reading) %RH -40 ... -20 °C (-40 ... -4 °F) ±(1.2 + 0.012 x reading) %RH +40 ... +60 °C (+104 ... +140 °F) ±(1.2 + 0.012 x reading) %RH -60 ... -40 °C (-76 ... -40 °F) ±(1.4 + 0.032 x reading) %RH Factory calibration ±0.6 %RH (0 ..
www.vaisala.com DTR500 Solar Radiation and Precipitation Shields • Nine-plate shield: Vaisala Radiation Shield DTR502B for HMT337, PTU300 and HMP155's additional T probe The special plastic used in the plates has excellent thermal characteristics; the white outer surface reflects radiation; the black inside absorbs accumulated heat. The shields can be easily installed on either a vertical pole, horizontal beam, or a flat surface.
Technical Data Dimensions Dimensions Dimensions in mm. Dimensions in mm. DTR502B for HMT337 and PTU300 DTR503A for HMP155 (ø105) (361) (437) (200) (266) (ø105) (213) DTR502B pole mast installation. DTR502B horizontal beam installation. (233) DTR503A pole mast installation. DTR503A horizontal beam installation. For more information, visit www.vaisala.com or contact us at sales@vaisala.com Ref.
www.vaisala.com HMT330MIK Meteorological Installation Kit 100 regular probe 95 90 warmed probe 85 80 75 1 2 3 4 5 6 7 After a period of 100 % relative humidity, the warmed probe measures the true humidity, whereas the non-warmed probe takes time to recover from the condensation. and the transmitter calculates the relative humidity from the dewpoint and temperature values. The HMT337 and PTU307 feature warmed probe technology.
Technical Data Dimensions Dimensions in mm (inches) 13 Ø220 (8.7) 211 (8.3) 299 (11.8) Ø105 (4.1) 371 (14.6) 160 (6.3) 40 (1.6) Ø100 (3.9) 645 (25.4) 800 (31.5) Order form Purchaser 800 (31.5) Valid from November 2006 d Order no.
www.vaisala.com HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air Measurement on the humidity sensor and thereby cause errors in measurement. The patented warmed probe prevents condensation from forming on the sensor. Protective Enclosure The HMT300TMK includes a white, painted stainless steel enclosure with an installation kit for the probe. The HMT337 Humidity and Temperature Transmitter is installed in the stainless steel enclosure at the factory, when ordered together with HMT300TMK.
Technical Data Dewpoint Temperature Outputs Measurement range -40 ... +100 °C (-40 … +212 °F) Accuracy: find the intersection of the dewpoint temperature curve and the dewpoint difference reading (process temperature - dewpoint temperature) on the x-axis and read the accuracy in dewpoint measurement at the y-axis Two standard outputs, third optional 0...20 mA, 4...20 mA, 0 ... 1 V, 0...5 V, 0 ...
Dew Point www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real time data and history. Features/Benefits ▪ Measures dew points from -60 °C to +80 °C (-76 ... +176 °F) with the accuracy of ±2 °C (±3.
Easy Installation The DMT340 has a variety of features to choose from. Units are delivered installation-ready. Dimensions Probe Specifications Dimensions in mm (inches) DMT342 with Small Size Flanged Probe Probe diameter up to 250 bar/ 3625 psia M6 71.5 (2.81) 12 mm/0.5 inch Installation Flange 36 mm/1.4 inch Sampling cell 45° HMP302SC 6 71 (2.80) Dimensions Probe Specifications Dimensions in mm (inches) up to 100 bar/ 1450 psia 12 mm/0.5 inch Ø 12 (0.47) 0 ... 50 bar/0 ...
Dimensions DMT347 with Small Sized Probe Mechanical durability Probe diameter The DMT347 probe is ideal for tight spaces with thread connection. The small probe is installed using the Swagelok® connectors. 41 (1.61) up to 10 bar/ 145 psia 12 mm/0.5 inch Installation Fitting Body R 3/8" ISO Fitting Body G 1/2" ISO Fitting Body NPT 1/2" Dimensions in mm (inches) DMT348 with Probe for Pipeline Installations Pressure range Adjustable length 41 ... 149/371 mm/ 1.61 ... 5.87/14.6 inch 41 (1.
Technical Data Measured Parameters Inputs and Outputs Dew point Sensor Measurement range For continuous use Accuracy up to 20 bar/290 psia 20 ... 50 bar/290 ... 725 psia Vaisala DRYCAP®180M -60 ... +80 °C (-76 ... +176 °F) Td -60 ... +45 °C (-76 ... +113 °F) Td ±2 °C/±3.6 °F see the accuracy graph below additional inaccuracy +1 °C Td Dew point accuracy vs. measurement conditions Response time 63% [90%] at +20°C gas temperature Flow rate 1 l/min and 1 bar pressure -60 ... -20 °C Td (-76 ...
Dimensions Cable bushing M20x1.5 for cable diameter 8 ... 11mm/0.31 ... 0.43” Conduit fitting 1/2”NPT User cable connector (optional) M12 series 8 pin (male) option 1 with plug (female) with 5 m / 16.4 ft black cable option 2 with plug (female) with screw terminals USB-RJ45 Serial Connection Cable order no. 219685 Probe cable diameter 5.5 mm Probe cable lengths 2 m, 5 m or 10 m Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4X) Dimensions in mm (inches) 77 (3.03) 71 (2.
Ensure dry compressed air with dewpoint measurement Vaisala innovated DRYCAP® dewpoint instruments have been developed for the most demanding conditions. ▪ ▪ ▪ ▪ Fastest wet-to-dry response time on the market - just minutes High resistance to contamination - immune to compressor oil Complete recovery from saturated conditions Long 2-year calibration interval Want to know more? Our experts welcome your most difficult questions. www.vaisala.com/compressedair sales@vaisala.
www.vaisala.com DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications The large and clear display allows the user to check data at a glance. The Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346 are designed to measure and control humidity especially in dry environments with high temperatures.
DMT346, Reliable in Very Hot Processes When process temperatures range between 140 °C to 350 °C, the DMT346 provides the best measurement performance. The DMT346 comes with a cooling set as a standard feature. The cooling effect may be regulated by adding the cooling fins, or removing them from the set for the best measurement performance.
Technical Data Measured Variables DMT346 Dewpoint DMT346 Sensor Measurement range Accuracy Vaisala DRYCAP®180S -25 ... +100 °C (-13 ... +212 °F) Td ±2 °C (±3.6 °F) Td See the accuracy graph below Dewpoint accuracy vs. measurement conditions Response time 63 % [90 %] flow rate 1 l/min and 1 bar pressure from dry to wet 5s [10 s] from wet to dry including auto-calibration 45s [5 min] Mixing Ratio DMT346 Measurement range (typical) Accuracy (typical) 0 ... 1000 g/kg (0 ...
Technical Data Dimensions Dimensions in mm (inches) DMT345 probe and mounting flange DMT345 and DMT346 Transmitter housing 75 (2.96) 28 (1.10) 75 (2.95) 12 (0.47) 77 (3.03) 71 (2.80) 13.5 (0.53) 50 (1.97) 41 (1.61) 27 (1.06) 2 (0.08) drilling 16...22 (0.63...0.87) 192 (7.56) 242 (9.53) 183 (7.20) 169 (6.65) DMT346 Cooling set 304 (11.97) 164 (6.46) 112.5 (4.43) 120 (4.72) 40.6 (1.6) ø105 (4.13) ø118 (4.65) ø28 (1.1) 8 15 (0.59) (0.31) ø89 (3.5) ø20 (0.79) ø7 (0.28) 96 (3.78) 116 (4.
www.vaisala.com DMT242 Dewpoint Transmitter for OEM Applications Due to its wide measurement range and high long-term stability, the DMT242 is an ideal choice for low dew point industrial applications such as compressed air dryers, plastic dryers and other OEM applications.
Technical Data Dew Point Temperature Operating Environment Measurement range (typical) -60 ... +60 °C (-76 ... +140 °F) Analog output scalings Option A -80 ...+20 °C (-112 ... +68 °F) Td Option B -60 ... +60 °C (-76 ... +140 °F) Td Option X free scaling (when the dew point is below 0 °C (32 °F), the transmitter outputs frost point) ±2 °C (±3.6 °F) Accuracy with DRYCAP® 180M (see graph below) Temperature higher temperature peaks Relative humidity Pressure Sample flow rate 0 ... +60 °C (32 ...
www.vaisala.com DMT152 Dewpoint Transmitter for Low Dewpoint Measurement in OEM Applications The small and powerful DMT152 measures dew point down to -80 °C.
Technical Data Measured Variables General Dew point temperature Sensor Accuracy not specified -30 -20 -10 0 10 20 30 40 50 60 70 Temperature of measured gas (°C) Response time 63 % [90 %] at a gas temperature of +20 °C (+68 °F) and pressure of 1 bar -10 ... -80 °CTd 0.5 min [7.5 min] -80 ... -10 °CTd 2 s [5 s] ppm volume concentration Measurement range (typical) Accuracy at +20 °C (+68 °F), 1013 mbar 0 ... 500 ppm ±(0.
www.vaisala.com DMT142 Miniature Dewpoint Transmitter for OEM Applications Features/Benefits ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Miniature size dew point transmitter for e.g. small industrial dryer applications Vaisala DRYCAP® technology with auto-calibration Calibration interval of two years Dew point measurement range -60 ... +60 °C (-76 ... +140 °F) with an accuracy ±3 °C (±5.
n ratio r satu o r vap Wate line Td ±3 °C r racy Accu or bette Td ±4 °C racy er Accu or bett rsion e Std v Dewpoint -30 -20 -10 0 10 20 ±3 °C e rang it lower lim ent range measurem 30 40 50 60 Temperature of measured gas (°C) Dewpoint accuracy range for the extended version. Standard version with dotted line. Dew point accuracy vs. measurement conditions Dew point accuracy range for the extended version. Standard version with dotted line.
www.vaisala.com DMT132 Dewpoint Transmitter for Refrigerant Dryers Features / Benefits ▪ Affordable dew point transmitter for refrigerant dryers ▪ High accuracy ±1°C (±1.8°F) in the measurement range of refrigerant dryers ▪ Excellent long-term stability resistant to compressor oil and most other chemicals thanks to HUMICAP® technology ▪ Low power requirements, 10 ...
Technical Data Performance General Dew point Sensor Vaisala HUMICAP®180R Recommended calibration interval 2 years (in refrigerant dryer application) Mechanical connection G 1/2" ISO Operating voltage 10 .... 28 VDC External load max 100 ohm for supply voltages <20 VDC max 500 ohm for supply voltages 20...28 VDC Weight 65 g (2.3 oz) Housing material PPS + 40% GF Housing classification IP65 (NEMA 4) Storage temperature range -40 ... + 80 °C (-40 ...
www.vaisala.com DMW19 Wall Mount Dewpoint Transmitters for Indoor Applications The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 is an easy and fast way to confirm the performance of DMW19 on site. Vaisala HUMICAP® Dewpoint Transmitter DMW19 is a compact wall mount dewpoint transmitter. Features/Benefits ▪ Designed for demanding building automation applications and other wall mount indoor applications where dewpoint measurement is needed ▪ Dewpoint measurement range -20 ...
Technical Data Dewpoint Temperature Dewpoint temperature (°C) Measurement range Accuracy 70 60 50 40 30 20 10 0 -10 -20 -30 -40 Operating Environment -20 ... +55 °C (-4 ... +131 °F) ±2 °C (±3.6 °F) (see graph below) Operating temperature Storage temperature Relative humidity -5 ... +60 °C (+23 ... +140 °F) -40 ... +80 °C (-40 ... 176 °F) 0 ...
www.vaisala.com DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications The Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dew point applications, such as compressed air, metal treatment and plastics drying. response from ambient to dry conditions exceptionally fast. The DM70 is fitted with the Vaisala DRYCAP® Sensor. The sensor provides reliable, stable and high-performance dew point measurement.
Technical Data Temperature Measurement range Accuracy at +20 °C (+68 °F) Typical temperature dependence of electronics Temperature sensor -10 ... +60 °C (+14 ... +140 °F) ±0.2 °C (±0.36 °F) ±0.005 °C/°C (±0.
www.vaisala.com DSS70A Portable Sampling System and Sampling Cells for DM70 The DSS70A provides a compact solution for field checking dew point where direct measurement is difficult. Typical applications for the sampling system are metal treatment and plastics drying processes. DSS70A Portable Sampling System The DSS70A is designed to provide dewpoint sampling flexibility for the DM70 hand-held dew point meter. For processes at atmospheric pressure, a battery powered pump is used to extract a gas sample.
Technical Data DMCOIL DMT242SC pressure limit DMT242SC2 DSS70A Sampling System and DSC74B/C Sampling Cells Filter Sample Gas Inlet Sampling Cell for Td Probe Needle Valve Flow meter Sample Pump Sample Gas Outlet pressure limit Material for all sampling cells DSS70A The DSS70A sampling system includes a filter to clean the dirty sample gas and a needle valve to control the sample flow rate with the flow meter. A sample pump is used to generate a sample flow from processes at ambient pressure.
www.vaisala.com DPT146 Dewpoint and Pressure Transmitter for Compressed Air Features/Benefits The DPT146 combines the knowledge of more than 20 years of sensortechnology development. Proven measurements from the DRYCAP® sensor for dew point and the BAROCAP® sensor for pressure are now combined into one easy-to-use transmitter. 128.5 120.
Technical Data Measured Parameters Dew point Pressure, absolute Temperature (available if output RS-485 only selected) -60 ... +30 °C (-76 ... +86 °F) 1 ... 10 bar (14.5 ... 145 psi) -40 ... +80 °C (-40 ... +176 °F) Calculated Parameters ppm moisture, by volume Dew point, converted to atmospheric pressure 1 ... 40 000 ppm -75 … +30 °C (-103 ... +86 °F) Performance Dew point accuracy ±2 °C (±3.6 °F) Pressure accuracy at 23 °C (73.4 °F) ±0.4 %FS Pressure temperature dependence ±0.
www.vaisala.com DPT145 Multiparameter Transmitter for SF6 Gas Features/Benefits The Vaisala Multiparameter Transmitter DPT145 with the DILO DN20 connector. The Vaisala Multiparameter Transmitter DPT145 for SF6 Gas is a unique innovation that enables online measurement of dew point, pressure, and temperature. It also calculates four other values, including SF6 density. The DPT145 is especially well suited for integration into OEM systems.
Technical Data Operating Environment Operating temperature of electronics -40 … +60 °C (-40 ... +140 °F) Operating Pressure 0 … 50 bar (0…725 psi) Relative humidity 0...100 % Measured gases SF6, SF6/N2 mixture Measured Parameters Dewpoint Pressure, absolute Temperature -50 ... +30 °C (-58 ... +86 °F) 1 ... 10 bar (14.5 ... 145 psi) -40 ... +80 °C (-40 ...
www.vaisala.com Dimensional Drawings of the DPT145 Multiparameter Transmitter 37 AW32 30.6 29.5 M45x2 52 8 44 80 7 44 20 83 200 AW8 4.8 30 AW50 160 51 57.7 59 The DPT145 with the DILO DN20 connector. 29.5 M30x2 AW27 G1/2 ISO 228-1 AW27 20 6 29.5 The DPT145 with the weather shield. 7 53.5 20 7 5 60 63.5 70 152 145.5 41.6 33 AW36 The DPT145 with the ABB Malmkvist connector. For more information, visit www.vaisala.com or contact us at sales@vaisala.
When Moisture is a Problem, Knowledge is Power. Literally. Protect Your High-Voltage Assets. How to revive an ageing fleet of high-voltage assets? Can you extend network lifetime and ensure performance? Just add knowledge – accurate, real-time moisture level information from transformers, switchgear, turbines, generators and diesel engines. It’s easy, affordable and fast.
Moisture in Oil www.vaisala.com MMT330 Moisture and Temperature Transmitter Series for Oil The display shows measurement trends, real time data and history. The MMT330 transmitter family offers a range of solutions for demanding moisture in oil measurements. ▪ Continuous on-line measurement of moisture in oil ▪ Ball valve installation – no need to shut down the process ▪ Proven Vaisala HUMICAP® Sensor, 15 years in oil applications.
Water Content as ppm Conversion In addition to water activity, the MMT330 can output ppm, the average mass concentration of water in oil. Vaisala has this conversion readily availabe for mineral transformer oil. For other oils, the oil specific conversion coefficients can be programmed to the transmitter if the water solubility of the oil is known. Graphical Measurement Trend and Historical Display The MMT330 can be ordered with a large numerical and graphical display with a multilingual menu.
Dimensions Installation Options Dimensions in mm (inches) 35 (1.38) Flange 36 mm / 1.4 inch 65.5 (2.58) -40 ... +180 °C (-40 ... 356 °F) Dimensions MMT337 with Small Sized Probe Pressure range Dimensions in mm (inches) ISO 3/8" or NPT1/2" Installation Options 0 ... 10 bar / 0 ... 145 psia Probe diameter 12 mm / 0.5 inch Installation Fitting Body R 3/8" ISO Fitting Body 1/2" ISO Fitting Body NPT 1/2" 33 (1.30) 77 (3.03) -40 ... +180 °C (-40 ...
Technical Data Measured Values Max wire size Water activity Measurement range aw 0 ... 1 Accuracy (including nonlinearity, hysteresis and repeatability) 0 ... 0.9 ±0.02 0.9 ... 1.0 ±0.03 Response time (90 %) at +20 °C in still oil (with stainless steel filter) 10 min. Sensor HUMICAP® Performance Temperature Measurement range MMT332 MMT337 MMT338 Accuracy at +20 °C (+68 °F) -40 ... +180 °C (-40 ... +356 °F) -40 ... +180 °C (-40 ... +356 °F) -40 ... +180 °C (-40 ... +356 °F) ± 0.2 °C (0.
Mounting Options Dimensions 71 (2.80) 77 (3.03) Dimensions in mm (inches) Mounting with DIN Rail Installation Kit 183 (7.20) Pole Installation with Installation Kit for Pole or Pipeline Ø 7 (0.28) 96 (3.78) 169 (6.65) 116 (4.57) Mounting with Wall Mounting Kit Mounting Rain Shield with Installation Kit HUMICAP® is a registered trademark of Vaisala. TYPE APPROVED PRODUCT CERTIFICATE NO.: A-11440 For more information, visit www.vaisala.com or contact us at sales@vaisala.com 92 Ref.
Don’t measure the damage. Prevent it. New intelligence for measuring moisture in oil. real time measurement ▪ On-line, without sampling ▪ ▪ Installation through ball valve – no need to shut down the process High stability in extreme conditions Know your oil better – Vaisala HUMICAP® instruments! Download the 'Top 8 FAQs - Measuring moisture in oil' at www.vaisala.com/mioFAQ Instruments display water activity trends. www.vaisala.com/lubrication sales@vaisala.
www.vaisala.com MMT310 Series Moisture and Temperature Transmitter for Oil Water Content as PPM Calculation for Transformer Oils PPM units are traditionally used in transformer applications. They indicate the average mass concentration of water in oil. The ppm calculation for mineral oil based transformer oil is optional in the MMT310 series. Diverse Applications and Demanding Conditions The MMT310 series can be used in lubrication and hydraulic systems as well as in transformers.
Technical Data Measured Values General Water activity Measurement range aw Accuracy (including non-linearity, hysteresis and repeatability) 0 ... 0.9 0.9 ... 1.0 Response time (90 %) at +20 ˚C in still oil (with stainless steel filter) Sensor 0 ... 1 ±0.02 ±0.03 10 min Vaisala HUMICAP® Temperature Measurement range Typical accuracy at +20 ˚C Typical temperature dependence of electronics Sensor -40 ... +180 ˚C (-40 ... +356 ˚F) ±0.1 ˚C (±0.18 ˚F) ±0.05˚C/ ˚C (±0.
www.vaisala.com MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM Applications Water Activity Measurement The MMT162 measures moisture in oil in terms of the water activity (aw) and temperature (T). Water activity directly indicates whether there is a risk of free water formation. The measurement is independent of oil type, age and temperature. The ppm calculation for mineral oil based transformer oil is optional in the MMT162.
Technical Data Measured Values General Water activity Sensor HUMICAP® Cable connections (2 ports) M8, 4 pin Minimum operating voltage with RS-485 output 14 ... 28 VDC voltage output 16 ... 28 VDC current output 22 ... 28 VDC Supply current normal measurement 20 mA + load current External load for voltage output min. 10 kOhm current output max.
www.vaisala.com MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in Oil Numerical and Graphical Display The MM70 features a multilingual, menu-based user interface and a backlit LCD display. The measurement parameters can be numerically and graphically displayed and logged into the meter's memory at the same time. An analog output option is also available. The MM70 is an ideal tool for the preventive maintenance of oil-filled systems.
Technical Data Performance Display Water activity Measurement range aw 0 ... 1 Accuracy (including nonlinearity, hysteresis and repeatability) When calibrated against salt solutions (ASTM E104-85): 0 ... 0.9 ±0.02 0.9 ... 1.0 ±0.03 Maximum achievable accuracy when calibrated against high-quality, certified humidity standards: 0 ... 0.9 ±0.01 0.9 ... 1.0 ±0.02 Response time (90%) at +20 °C (+68 °F) in still oil (with stainless steel filter) 10 min.
Carbon Dioxide www.vaisala.
Technical Data PRESSURE Inputs and Outputs Effect on accuracy with pressure compensation: CO2 range options 0 ... 1000 ppm 0 ... 2000 - 2 % Pressure (hPa) Accuracy (% of reading) 900 ... 1050 ±0.5 ±1 700 ...
www.vaisala.com GMT220 Series Carbon Dioxide Transmitters for Industrial Applications The GMT220 transmitters withstand harsh and humid environments.
Technical Data Performance Operating Environment Measurement Ranges GMT221 for high concentrations 0 ... 2 % 0 ... 3 % 0 ... 5 % 0 ... 10 % 0 ... 20 % 0 ... 2000 ppm 0 ... 3000 ppm 0 ... 5000 ppm 0 ... 7000 ppm 0 ... 10 000 ppm Accuracy (including repeatability, non-linearity and calibration uncertainty) at 25 °C and 1013 hPa GMT221 ±(1.5 % of range + 2 % of reading) (applies for concentrations above 2 % of full scale) GMT222 ±(1.5 % of range + 2 % of reading) Temperature dependence, typical -0.
www.vaisala.com GMM220 Carbon Dioxide Modules for Demanding OEM Applications The Vaisala CARBOCAP® Carbon Dioxide Module Series GMM220 withstand harsh conditions.They provide high carbon dioxide measurement accuracy over wide temperature and relative humidity ranges.
Technical Data Carbon Dioxide Mechanics Measurement ranges GMM221 for high concentrations Probe housing material PC plastic Housing classification (probe only) IP65 Weight: GMM221 (w/2m cable) max. 180 g Weight: GMM222 (w/2m cable) max. 200 g Probe cable length 0.6 m, 1 m (high temperature cable), 2 m, 6 m or 10 m (optional) 0 ... 2 %, 0 ... 3 %, 0 ... 5 %, 0 ... 10 %, 0 ... 20 % GMM222 for low concentrations 0 ... 2000 ppm, 0 ... 3000 ppm, 0 ... 5000 ppm, 0 ... 7000 ppm, 0 ...
www.vaisala.com GMM111 Carbon Dioxide Module The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement module with flow-through aspiration. Features/Benefits ▪ Compact CO2 module with flow-through aspiration ▪ Ideal for control of CO2 concentrations in incubators ▪ Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing ▪ Advanced single-beam, dual wavelength measurement with no moving parts ▪ Measurement range options 0 ... 5 %, 0 ...
Technical Data Dimensions CO2 measurement range 0 ... 5 %, 0 ... 10 % or 0 ... 20 % Accuracy (including repeatability, non-linearity and calibration uncertainty) ±(1.5% of range + 3 % of reading) Long-term stability ±5 % FS/2 years 1 min at 0.5 l/min flow Response time T90 Dimensions in mm Product lifetime 96 Ø3.2 65 no effect 4 % of reading/ l/min -0.3 % of reading/°C +0.15 % of reading/hPa 1 min, 10 min for full specifications > 10 years mA V 0 B A 0 24V TUBE I.D. Ø4 (TUBE O.D.
www.vaisala.com GM70 Hand-Held Carbon Dioxide Meter for Spot-Checking Applications accuracy is not affected by dust, water vapor or most chemicals. The GM70 has a two-year recommended calibration interval. The Vaisala CARBOCAP® Hand-Held Carbon Dioxide Meter GM70 is the demanding professional’s choice for hand-held carbon dioxide measurement.The meter consists of the indicator (center) and probe, used either with the handle (left) or pump (right).
Technical Data CO2 Volume Concentration Measurement MI70 Indicator General Measurement ranges High concentrations short probe (GMP221) Menu languages 0 ... 2 % 0 ... 3 % 0 ... 5 %, 0 ... 10 %, 0 ... 20 % Low concentrations 0 ... 2000 ppm long probe (GMP222) 0 ... 3000 ppm, 0 ... 5000 ppm, 0 ... 7000 ppm, 0 ... 10,000 ppm Accuracy (including repeatability, non-linearity and calibration uncertainty) at 25 °C and 1013 hPa GMP221 ±(1.
www.vaisala.com GMW116 Carbon Dioxide and Temperature Transmitter for Ventilation Control The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116. Features/Benefits ▪ ▪ Compact dual-parameter transmitter: measures both CO2 and T Incorporates Vaisala CARBOCAP®, the silicon based NDIR sensor with unique internal referencing The Vaisala CARBOCAP® Carbon Dioxide and Temperature Transmitter GMW116 is the compact-size transmitter that measures both carbon dioxide and temperature.
Technical Data Performance Dimensions CO2-measurement range Temperature measurement range Accuracy (including repeatability, nonlinearity and calibration uncertainty) Long-term stability Response time T90 Temperature dependence Pressure dependence, typical Temperature measurement accuracy Warm-up time Product lifetime 0 ... 2000 ppm 0 ... +50 °C ± (2 % of range + 2 % of reading ± 5 % of range/5 years 1 min compensated +0.15 % of reading/hPa ± 0.7 °C at 25 ° 1 min, 10 min for full.
www.vaisala.com GMW115 Carbon Dioxide Transmitter for Demand-controlled Ventilation from the stable reference provided by the electrically tunable Fabry-Perot Interferometer (FPI). The Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW115 is a wall-mounted CO2 transmitter for demand-controlled ventilation.
Technical Data Dimensions 66.3 60 .2 120.9 60 R2.1 Temperature -5 ... +45 °C (23 ... 113 °F) Humidity 0 ... 85 %RH Pressure 700 ... 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1, Generic Environment 25.8 Operating Environment R3.5 84 Inputs and Outputs Operating voltage Power consumption Outputs 124 Ø4 66.7 Product lifetime Dimensions in mm 85 .
www.vaisala.com GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation Applications affected by dust, water vapor and most chemicals. Versatile Transmitters The GMD/W20 series transmitters can be used independently, or incorporated into building energy management systems. The series consists of duct mount units GMD20/D and wall mount units GMW21/D and GMW22/D. Version D has a display. The two sizes in the wall-mount series make them easy to install for most standard junction boxes.
Technical Data Performance Accessories and Options CARBON DIOXIDE MEASUREMENT Display and relay option for GMD/W21/22 Relay output option LonWorks® module with CO2 signal (Not available when display option is added) LonWorks® module with both CO2 signal and temperature signals (Not available when display option is added) Serial COM adapter Analog temperature module for GMW21 (not available when display option is added) Hand-held meter for field verification Measurement range 0 ...
www.vaisala.
Technical Data Dimensions Operating Environment Temperature -5 ... +45 °C (23 ... 113 °F) Humidity 0 ... 85 %RH Pressure 700 ... 1200 hPa Electromagnectic compatibility Complies with EMS standard EN61326-1:1997 + Am1:1998, Generic Environment Inputs and Outputs Operating voltage Power consumption Outputs 24 V (±20 %) AC/DC <2 W 4 … 20 mA, 0 … 10 V, RS-485, 2-wire, non-isolated For more information, visit www.vaisala.com or contact us at sales@vaisala.com mA V 0 B A 0 24V mA V 0 B A 0 24V Ø3.
www.vaisala.com GMM20W Carbon Dioxide Module for OEM Applications Features/Benefits The Vaisala CARBOCAP® Carbon Dioxide Module GMM20W is designed for OEM applications in benign environments.
Technical Data Performance Dimensions CARBON DIOXIDE MEASUREMENT Dimensions in mm Measurement range 0 ... 2000 ppm (nominal; can be calibrated for other ranges: 0 ... 5000 ppm, 0 ... 10,000 ppm, 0 ...
Pressure www.vaisala.com PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding Applications over four years of measured history, and zoom in on any desired time or time frame. The battery backup of the real-time clock guarantees a reliable logging of measured data. The display alarm allows tracking of any measured parameter, with a freely configurable low and high limit.
PTU300 Models Dimensions Dimensions in mm (inches) 120 (4.72) 12 (0.47) PTU301 for wall mounting Dimensions Dimensions in mm (inches) 116 (4.57) 183 (7.20) 106 (4.17) PTU301 short cable probe 42 (1.65) Dimensions M9x1 Ø 12 (0.47) Dimensions in mm (inches) 37.5 (1.48) PTU303 for outdoor use 78.5 (3.09) 98.5 (3.
PTU300 Models Dimensions M9x1 Ø 12 (0.47) Dimensions in mm (inches) 37.5 (1.48) 79.5 (3.13) PTU307 warmed probe for demanding meteorological installations Ø 6 (0.24) Ø 3.2 (0.13) 99.5 (3.92) 130 (5.12) Dimensions Ø 6 (0.24) Ø 3.2 (0.13) Dimensions in mm (inches) 130 (5.
Technical Data Performance Barometric pressure Pressure range Accuracy 500 ... 1100 hPa, 50 ... 1100 hPa 500 ... 1100 hPa 500 ... 1100 hPa 50 ... 1100 hPa Class A Class B Linearity ±0.05 hPa ±0.10 hPa ±0.20 hPa Hysteresis* ±0.03 hPa ±0.03 hPa ±0.08 hPa Repeatability* ±0.03 hPa ±0.03 hPa ±0.08 hPa Calibration ±0.07 hPa ±0.15 hPa ±0.20 hPa uncertainty** Accuracy at +20 °C*** ±0.10 hPa ±0.20 hPa ±0.30 hPa Temperature ±0.1 hPa ±0.1 hPa ±0.3 hPa dependence**** Total accuracy ±0.15 hPa ±0.25 hPa ±0.
Mechanics Cable bushing M20 x 1.5 for cable diameter 8 ... 11 mm/0.31 ... 0.43" Conduit fitting 1/2" NPT User cable connector (optional) M12 series 8-pin (male) option 1 female plug with 5 m (16.4 ft) black cable option 2 female plug with screw terminals Probe cable diameter PTU303 6.0 mm other probes 5.5 mm Housing material G-AlSi 10 Mg (DIN 1725) Housing classification IP 65 (NEMA 4) Weight depending on selected probe 1.5 ... 2.
Measure Monitor AND Validate in Controlled Environments Humidity - Temperature - CO2 - dP - AND MORE ... Watch a brief online video about Vaisala Veriteq Continuous Monitoring System. www.vaisala.com/cms www.vaisala.com/lifescience-hitech sales@vaisala.
www.vaisala.com PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial Users against one another and provides information on whether these are within the set internal difference criteria. This unique feature provides redundancy in pressure measurement. Thus, users also get a stable and reliable pressure reading at all times as well as a pre-indication of when to service or recalibrate the barometer. QNH and QFE Vaisala BAROCAP® Digital Barometer PTB330 with a new trend display.
Technical Data Performance Inputs and Outputs Barometric pressure range 500 ... 1100 hPa Linearity* Hysteresis* Repeatability* Calibration uncertainty** Accuracy at +20 °C (+68 °F) *** Class A ±0.05 hPa ±0.03 hPa ±0.03 hPa ±0.07 hPa ±0.10 hPa Class B ±0.10 hPa ±0.03 hPa ±0.03 hPa ±0.15 hPa ±0.20 hPa Barometric pressure range 50 ... 1100 hPa Class B ±0.20 hPa ±0.08 hPa ±0.08 hPa ±0.15 hPa ±0.
www.vaisala.com Take the Lab to the Field Vaisala Barometric Pressure Transfer Standard PTB330TS Operational PTB330TS unit includes a PTB330 digital barometer, hand-held MI70 indicator, optional HMP155 humidity and temperature probe, optional MI70 Link PC software, a user’s guide and a weatherproof transfer case equipped with a shoulder strap. PTB330TS transport case Barometric Pressure Transfer Standard PTB330TS makes field inspection accurate and easy.
The PTB330 Digital Barometer The HMP155 probe The MI70 hand-held indicator displaying the prevailing pressure in hPa PTB330 Digital Barometer information on whether these are within the set internal difference criteria. This unique feature provides redundancy in pressure measurement. Thus, users get a stable and reliable pressure reading at all times as well as a pre-indication of when to service or re-calibrate the barometer.
www.vaisala.com Vaisala Barometric Pressure Transfer Standard PTB330TS Technical Data These specifications apply when MI70, PTB330 and HMP155 are used together in the PTB330TS product. For individual specifications, please refer to the product documentation and brochures of the PTB330 and HMP155. General Operating temperature range Operating humidity range Maximum pressure limit Power supply -10 ... +40 °C (+14 ... +104 )°F non-condensing 5000 hPa abs.
Technical Data Available Parameters Accessories Pressure parameters Humidity and temperature parameters P, P3h, HCP, QFE, QNH RH, T, Tdf, Td, x, Tw Inputs and Outputs MI70 probe ports MI70 data interface PTB330 supply voltage PTB330 data interface PTB330 serial I/O connectors HMP155 data interface HMP155 serial I/O connector 2 RS-232 (accessible only with MI70 Link software) 10 ...
www.vaisala.com PTB210 Digital Barometer The PTB210 paired with the SPH10 Static Pressure Head. The Vaisala BAROCAP® Digital Barometer PTB210 is a reliable outdoor barometer that withstands harsh conditions. For harsh environments The Vaisala BAROCAP® Digital Barometer PTB210 is ideal for outdoor installations and harsh environments. The barometers are designed to operate in a wide temperature range, and the electronics housing provides IP65 (NEMA 4) standardized protection against sprayed water.
Technical Data Operating range (1hPa=1mbar) General Pressure range (order specified) serial output (• Factory setting) analog output Operating temperature range Humidity range 500 ... 1100 hPa 50 ... 1100 hPa 500 ... 1100 hPa 600 ... 1060 hPa 800 ... 1060 hPa 900 ... 1100 hPa -40 ... +60 °C (-40 ...
Technical Data Dimensions 122.5 (4.82) 32 (1.26) 16 (0.63) 120 (4.72) Dimensions in mm (inches) 50 (1.97) BAROCAP® is a registered trademark of Vaisala. For more information, visit www.vaisala.com or contact us at sales@vaisala.com 134 Ref. B210942EN-A ©Vaisala 2010 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners.
Calculate and Convert. The free web based Vaisala Humidity Calculator allows you to calculate several humidity parameters from one known humidity value. Make unit conversions on the fly, and see the effects of changing ambient conditions, like temperature and pressure. The calculator is available in several languages. Access or download the Vaisala Humidity Calculator at www.vaisala.com/humiditycalculator Available also at the Apple iTunes App Store www.vaisala.
www.vaisala.com PTB110 Barometer for Industrial Use The Vaisala BAROCAP® Barometer PTB110 offers outstanding long-term stability. Features/Benefits ▪ ▪ ▪ ▪ ▪ Vaisala BAROCAP® sensor ▪ Output voltage 0 ... 2.5 or 0 ... 5 VDC ▪ Current consumption less than 4 mA ▪ Mountable on a (35 mm wide) DIN rail ▪ NIST traceable (certificate included) 136 Several pressure ranges Accuracy ±0.
Technical Data Operating Range (1 hPa=1mbar) Accuracy Pressure ranges Linearity* ±0.25 hPa Hysteresis* ±0.03 hPa Repeatability* ±0.03 hPa Calibration uncertainty** ±0.15 hPa Accuracy at +20 °C*** ±0.3 hPa * Defined as ±2 standard deviation limits of end-point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST.
www.vaisala.com SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error Wind induced effects are one of the main sources of error when measuring barometric pressure. Variations due to strong and gusty wind can be overcome by using a static pressure head to ‘filter out’ the effect of dynamic pressure. The Vaisala Static Pressure Head Series SPH10/20 are designed to minimize the errors caused by wind. The wind tunnel tested structure is both horizontally and vertically symmetrical.
Technical Data General Operating temperature Weight SPH10 SPH20 Material Mounting Hose connection SPH20 -60 ... +80 °C (-76 ... +176 °F) 800 g 1360 g PC plastic, offshore aluminium with 2 bolts (M6 X 20 mm min) barbed fitting for 4 mm I.D. hose or Rp1/4 thread (parallel) Electrical connections Power supply M12 connector factory setting 12 V changed connection 24 V Thermostat switching temperature On Off Power consumption during heating +4 °C (±3 °C) +39.2 °F (±4.4 °F) +13 °C (±3 °C) +55.4 °F (±4.
www.vaisala.com Vaisala Differential Pressure Transmitter PDT102 Vaisala Differential Pressure Transmitter PDT102 with process valve actuator and test jacks. Features ▪ ▪ ▪ ▪ ▪ ▪ In-place system calibration and on-line monitoring without disturbing process tubes with optional process valve actuator and test jacks Ultrathin profile ideally suited for DIN rail mount reduces installation and calibration costs High accuracy, two options; 0.25% or 0.
Technical Data Performance Mechanics Measurement ranges (bidirectional) ±50 Pa ±0.25 in H2O Overpressure proof pressure 0.7 bar burst pressure 1.7 bar static pressure 1.7 bar Pressure type differential, gauge, vacuum and compound Accuracy 0.25 % span or 0.5 % span, depending on choice Repeatability for 0.25 % span accuracy 0.03 % for 0.5 % span accuracy 0.05 % Electrical resolution 1 x 10-4 span Long-term stability ≤0.5 % span/year Response time (10 ...
www.vaisala.com Vaisala Differential Pressure Transmitter PDT101 Vaisala Differential Pressure Transmitter PDT101 with current output (black) and voltage output (green).
Technical Data Performance Mechanics Measurement ranges (bidirectional) ±60 Pa ±0.25 in H2O Overpressure proof pressure 1.0 bar burst pressure 1.7 bar static pressure 1.7 bar Pressure type differential, gauge, vacuum and compound Accuracy (terminal point, incl. effect of linearity, hysteresis and repeatability) 0.4 % span Long-term stability ≤0.5 % span/year Response time (10 ... 90 %) 250 ms Warm-up time 15 s Compensated temperature range +2 ... +54 °C (+35.6 ... +129.2 °F) Temperature dependence ±0.
Weather www.vaisala.com Vaisala Weather Transmitter WXT520 Access to Real Time Weather Data The WXT520 has an automatic control circuit that switches the heating on at low temperatures.
Technical Data Wind Air Temperature Speed range response time accuracy 0 ... 35 m/s 35 m/s ... 60 m/s output resolutions and units 0 ... 60 m/s 250 ms ±0.3 m/s or ±3%, whichever is greater ±5% 0.1 m/s, 0.1km/h, 0.1 mph, 0.1 knots Δ °C 0.7 0.6 0.5 0.4 0.3 0.2 0.1 °C 0 -0.1 -0.2 -0.3 Direction -0.4 azimuth response time accuracy output resolution and unit 0 ... 360° 250 ms ±3° 1° Liquid Precipitation Rainfall Range -52 ... +60 °C (-60 ... +140 °F) Accuracy for sensor at +20 °C ±0.3 °C (±0.
www.vaisala.com WMT52 Ultrasonic Wind Sensor for Accurate and Stable Measurement Applications The WMT52 is ideal for use in marine applications as the housing with the mounting kit is water resistant. The WMT52 is also suitable for wind energy and environmental monitoring, for example, for measuring the distribution of air pollution and road tunnel ventilation. Easy to Install The WMT52 is delivered fully assembled and configured from the factory.
Technical Data Wind Power Supply Wind speed Range Response time Available variables Accuracy 0 ... 35 m/s 35 m/s ... 60 m/s Output resolution 0 ... 60 m/s 250 ms average, maximum, and minimum ±0.3 m/s or ±3 % whichever is greater ±5 % 0.1 m/s (km/h, mph, knots) Wind direction Azimuth Response time Available variables Accuracy Output resolution 0 ... 360° 250 ms average, maximum, and minimum ±3° 1° Measurement frame Averaging time Update interval 1 ...
www.vaisala.com WA15 Wind Set for High Performance Wind Measurement per revolution. This generates a pulse output from the phototransistor. The output pulse rate is directly proportional to wind speed (e.g. 246 Hz = 24.6 m/s). However, for the highest accuracy, the characteristic transfer function should be used to compensate for starting inertia. (See technical data.) Sensitive Wind Vane The WA15 is based on accurate sensors installed on a large crossarm.
Technical Data Vaisala Anemometer WAA151 Vaisala Wind Vane WAV151 Wind Speed Wind Direction Measurement range 0.4 ... 75 m/s Starting threshold < 0.5 m/s * Distance constant 2.0 m Characteristic transfer function U = 0.328 + 0.101 × R (where U = wind speed [m/s], R = output pulse rate [Hz]) Accuracy (within range 0.4 ... 60 m/s) with characteristic transfer function ± 0.17 m/s ** with transfer function U = 0.1 × R ± 0.5 m/s*** Measurement range at wind speed 0.4 ...
Vaisala Service Offering Vaisala Service Offering High precision instruments need to be calibrated on a regular basis to ensure continued optimal performance. Vaisala offers a standard (service center) calibration for almost all of its equipment. The measurement points are defined and the calibrations are sold as products with a fixed price. These calibrations are traceable and ISO 9001 compliant (ANSI-Z540-1-1994 in our US Service Center).
Calibration is Our Core Operation Standard (Service Center) Calibrations Service Center European Service Center China Service Asian Service North American Center Center Service Center Location Helsinki, Finland Beijing, China Tokyo, Japan Boston, MA, USA Humidity √ √ √ √ Temperature √ √ √ √ Dew Point Temperature √ √ √ √ Barometric Pressure √ √ √ Table 1. Standard (service center) calibration is available globally in all Vaisala Service Centers.
Vaisala Filters Group A: 12 mm Diameter, Standard Length, Female Threads 0195 Brass, sintered filter, 133 microns, ø 12.0 mm Group: A 10159HM Membrane filter, 0.2 microns, ø 12.0 mm Group: A 10159HM 0195 6221 Plastic grid, 2 mm protection, ø 12.0 mm Group: A 6221 230727SP Membrane filter, 0.2 microns, ø 12.0 mm Group A 230727SP Group B: 12 mm Diameter, Long Length, Female Threads (Could be used in place of “A” type filters) DRW010276SP PPS plastic grid filter, 6.
Vaisala Filters continued Group C: 12 mm Diameter, Male Threads 17039HM Membrane filter 0.2 µm, ø 12 mm Group: C 17039HM DRW010522 Plastic Grid, 2 mm, ø 12 mm Group: C DRW010522 HM46670SP Sintered stainless steel filter , 38 µm, ø 12.0 mm Group: C HMM46670SP DRW010525 Membrane filter, 0.2 µm, ø 12 mm Group: C DRW010525 Group D: 13.5 mm Diameter, Male Threads 16452SP Sintered filter, stainless steel, 37 microns, ø 13.5 mm Group: D 16452SP 17230HMSP PTFE membrane, 3.5 µm, ø 13.5 mm.
Vaisala Filters continued Group E: 18.5 mm Diameter, Female Threads 2787HM Membrane filter, 0.2 microns, ø 18.5 mm Group: E 6597 Plastic grid, 2.5 mm, ø 18.5 mm Group: E 6597 2787HM HM46717 Plastic grid, 2.5 mm, ø 18.5 mm Group: E 16126HM Metallized membrane filter, 0.5 µm, ø 18.5 mm Group: E 16126HM HM46717 Stand Alone - Not Interchangeable: HM46780 Stainless steel filter, 38 µm, ø 20 mm HM46780 154 19858HM Membrane filter tube set (5 pcs) HMP42 probe, 0.
155
Vaisala Contact Information EUROPE FINLAND Vaisala Oyj P.O.Box 26 FI-00421 Helsinki FINLAND Tel. +358 9 894 91 Fax +358 9 8949 2485 sales@vaisala.com www.vaisala.com BENELUX Contact: Bonn Office Adenauerallee 15 D-53111 Bonn GERMANY Tel. +49 228 24971 23 Fax +49 228 24971 11 Toll free Netherlands : 00800 -282 472 52 Toll free Belgium: 0800 17 200 benelux.sales@vaisala.com www.vaisala.com FRANCE Vaisala SAS Lyon Office 12, Avenue des Saules F-69922 OULLINS Cedex FRANCE Tel.
NORTH AMERICA ASIA AND PACIFIC Vaisala Inc. Boston Office 10-D Gill Street Woburn, MA 01801 USA Tel. +1 781 933 4500 Toll free 1-888-VAISALA (824-7252) Fax. +1 781 933 8029 instruments@vaisala.com www.vaisala.com AUSTRALIA Vaisala Pty Ltd Melbourne Office 3 Guest Street Hawthorn, VIC 3122 AUSTRALIA Tel: +61 3 9815 6700 Fax: +61 3 9815 6799 Freecall: 1800 335 840 sales.melbourne@ vaisala.com www.vaisala.com Vaisala Inc. Houston Office 1120 NASA Road, Suite 220-E Houston, TX 77058, USA Tel.
Calculate and Convert. The free web based Vaisala Humidity Calculator allows you to calculate several humidity parameters from one known humidity value. Make unit conversions on the fly, and see the effects of changing ambient conditions, like temperature and pressure. The calculator is available in several languages. Access or download the Vaisala Humidity Calculator at www.vaisala.com/humiditycalculator Available also at the Apple iTunes App Store www.vaisala.
www.vaisala.com For more information, visit www.vaisala.com or contact us at sales@vaisala.com Ref. B210974EN-B ©Vaisala 2011 This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners.