Technical data
Instructions on commissioning, maintenance, and troubleshooting for auroSTOR 0020111119_02 21
Unit VIH S GB 210/2 S VIH S GB 260/2 S VIH S GB 310/2 S
Electrical connections
Immersion heater (according to EN BS 60335) 2.7 kW, 230 V, 50 Hz
Length of immersion heater inch 14
Two port motorised valve 230/240 V, 50 Hz
Cylinder thermostat 230/240 V, 50 Hz
Thermal cut-out solar 230/240 V, 50 Hz
Material data
Cylinder body material Stainless steel (1.4521)
Cylinder jacket material Polypropylene
Insulation material EPS with infrared absorber
Insulation thickness mm 50
Corrosion protection Stainless steel
Blowing agent for insulation material Pentane (GWP < 5)
ODP 0
Tab. 4.2 Technical data for auroSTOR solar cylinder (continued)
i
The heat up time is based on a flow rate
of 1400l/h at 80 ºC.
Temperature rise from 15 ºC to 60 ºC.
Description of the components 4