Operating instructions
14
Operating instructions ecoTEC plus 0020124810_FT1b
4.4.2 Setting the heating flow temperature 
with a controller
If your gas-fired wall-hung boiler has a room thermostat 
control system or weather compensator, make the 
following settings:
 > Press the on/off switch to switch on the boiler.
 > Set the maximum heating flow temperature 
(¬ section 4.4.1).
The flow temperature is automatically adjusted by the 
controller (for information see the controller operating 
instructions).
4.5   Hot water production with VUW units
4.5.1   Setting the hot water temperature
a
 Danger!
Risk of being scalded by hot water!
There is a danger of scalding at the hot water 
draw-off points if the hot water temperatures 
are greater than 60 °C. Young children and 
the elderly can even be at danger at lower 
temperatures.
 > Select the temperature so that nobody 
is at risk.
a
 Danger! 
Possible danger to life from legionella! 
If the unit is used to reheat water in a solar-
based drinking water heating system, note the 
following:
 > Set the minimum hot water temperature 
to 60 °C.
b
  Caution!
Material damage due to calcification.
If the water hardness is more than 
-3.57 
mol/m
3
 (20 °dH), there is a risk 
of calcification.
 > Set the maximum water temperature 
to 50 °C.
1
2
4
3
Fig. 4.7   Setting the hot water temperature
 > Press the on/off switch (1) to switch on the boiler.
 > Set the hot water temperature by pressing the 
following sequence of keys:
"Operating mode" selection button 
 --> "Next"
The hot water temperature is shown on the display.
 > Change the hot water temperature with the "Scroll 
down" (3) or "Scroll up" (4) arrow keys. 
 > Confirm the changes by pressing the "OK" selection 
button (2).
The new hot water temperature is now set.
 > Press the "Next" or "Back" selection button until you 
have reached the desired level or the basic display.
If you do not press any buttons for more than 
15 minutes, the display returns to the basic display.
If your controller is connected to the boiler via a two-
wire eBUS cable, then you can set the hot water target 
temperature on the controller.
Ask your approved heating engineer whether or not 
your controller is connected via a two-wire eBUS cable.
If your controller is connected via a two-wire eBUS:
 > Set the hot water temperature on the boiler 
to the maximum possible temperature.
 > Set the desired hot water temperature 
(hot water target temperature) on your controller.
4.5.2  Activating/deactivating comfort mode
Comfort mode immediately supplies you with hot water 
at the required temperature, without you having to wait 
for the water to heat up. To do this, the hot water heat 
exchanger of the ecoTEC plus is kept at your selected 
temperature level.
4 Operation