Technical data

Installation 5
uniSTOR GB 17
All internal wiring is factory mounted.
The thermostat which controls the DHW temperature (1,
fig. 10) is adjustable between 20 and 65 °C. The built in
safety thermal cut out operates at 90 °C. Should the
thermal cut out be brought into operation, the
motorized 2 port valve will be operated and shut the
primary flow to the cylinder. Press the reset button (2,
fig. 10) to reset thermal cut out and motorised valve.
Important:
Before resetting the thermal cutout or changing
the temperatur setting of the thermostat, set
the electrical supply off.
Connections to wiring box
Provide a wiring box adjacent to the cylinder to make
the electrical connections.
Connect the boiler terminals to the corresponding
terminals of the wiring box.
Connect the uniSTOR cylinder controls to the wiring
box as shown in figure 10.
Connect the 2 port valve flying lead to the terminals
of the wiring box.
Connect the terminals of the programmer and room
thermostat to the terminals of the wiring box.
Connect a 3 amp fused mains supply to the terminals
of the wiring box.
Note:
All wiring must be carried out in accordance with
BS 7671: Requirements for electrical installations
(IEE Wiring Regulations, 16th edition).
Check that the sensors from the immersion heater
and the cylinder are positioned correctly in the tubes.
Note:
A special accessory is offered for the electrical
connections between the uniSTOR and an
ecoEURO appliance (No. 307 215).
5.4.5.3 Connection details for control systems utilising 2 x 2 port motorised valves via external
wiring box
Fig. 11 Connection details for control systems utilising 2 port motorised valve
Diagram only applies to the specific controls mentioned
LN
LN
345
N L
CENTRAL
HEATING
ON
HOT
WATER
ON
HOT
WATER
OFF
3 amp fused
main supply
ecoTEC
terminal strip
Programmer
for programmer connections see fig. 16.d
LN
LN
345
5367 8
External wiring box
345678910
N
N
L
L
(Do not use pre-wired printed circuit board type)
not used
EARTH BLUE BROWN GREY ORANGE
Hot water 2 port motorised valve
4E5 310
ECA
N
4
N
4
2
4
4
3
3
3
3
3
2
2
2
2
1
1
L
2
1
L
1
1
1
1
3
CB
E
E
E
E
Vaillant VRT 9090
ACL Drayton Digistat 2, 3, 4
ACL Drayton RTS 1, 2
Danfoss Randall RX-1
Danfoss Randall RMT 230
Danfoss Randall RET 230
Tower SS
Honeywell T6360
Horstmann HRT 1
Siemens-Landys & Staefa RAD 1
Sunvic TLX 2000 series
5 9 6 L N E
Room thermostat
23E1
10
7 E
uniSTOR Cylinder
E
EARTH BLUE BROWN GREY ORANGE
Central heating 2 port motorised valve
4E5 39