Technical data
Type VUW VUW
242/1 E B 282/1 E B
Countries of
GB, IE GB, IE
Destination
Main burner jet size 16 x 7/075 18 x 7/075 number x mark.
Burner setting pressure 25.1 (9.9) Propane 26.6 (10.5) Propane mbar (in W.G.)
19.3 (7.6) Butane 20.6 (8.1) Butane mbar (in W.G.)
Restrictor 2 * 350 2 * 375 marking
Delivered gas
Propane G 31 96.65 MJ/m
3
Gross C.V. (s.t.) G 30 125.81 MJ/m
3
Gas consumption (s.t.) 1.09 (Propane) 1.27 (Propane) m
3
/h
0.84 (Butane) 0.98 (Butane) m
3
/h
59
Technical Data
L.P.G. Appliances:
VUW 242/1 EB
VUW 282/1 EB
The appliance delivered is designed
for use with LPG.
Please read the instructions for
installation therefore as follows:
Related documents to be
supplemented by:
BS 5482: CP for domestic butane
and propane gas
burning installations
Part 1: Installations in
permanent dwellings
Inlet pressure: Propane
37 mbar (14.6 inW.G.)
Butane
28-30 mbar
(11.0-11.8 in W.G.)
11. Supplementary
information for
TURBOmax