Technical data
50
Does sparking start?
Go to sheet .H
Does yellow ignition indicator
( ) flash after 30s?
Replace electronic boards.
Check operation of differential pressure switch
Sheet F
Has system been filled with
water?
Is solenoid activated?
Is differential pressure switch
activated?
Check for dirt or damage to
the differential switch, supply
tubes and diaphragm.
Go to sheet G.
Yes
Yes
No
Yes
No
No
No
Yes
Fill and vent system and
boiler.
No
Check continuity of
microswitch. Replace if
necessary. Check connection
of ribbon plug to switch board.
If burner still fails to light,
replace electronic boards.
Yes