Technical data

42
1
2
fig. 74
GW 650/2
7.18 Replacement of DHW
microswitch.
Isolate appliance from electricity
supply.
Remove front casing as in section
7.1.3.
Lower front control panel as in
section 7.1.6.
Lift off microswitch retaining bow
spring,
Pull microswitch forward to remove
from mounting bracket and
disconnect wires.
Reassemble in reverse order.
Carry out electrical checks (see
section 5.1).
7.19 Replacement of DHW heat
exchanger
Turn off boiler as in section 7.1.1.
Remove front casing as in section
7.1.3.
Release CH water pressure and
drain boiler as in section 7.1.2.
Lower front control panel as in
section 7.1.6.
Unscrew the top two unions (1, fig.
74), bottom left hand union and
backnut (2, fig. 74)
Note: The connection between the
DHW heat exchanger and water
section is a push fit joint.
Pull heat exchanger forward to
remove.
Reassemble in reverse order using
new sealing rings supplied.
Refill and repressurise the boiler
(see Section 5.4).