Specifications
4 turboMAX
plus
Green warmstart indicator
(3)
llluminated
=
Warmstart
switched
ON
Not illuminated
=
Warmstart is switched
OFF and there
is no
demand for hot water
Flashing
=
There is
either a demand for hot water
or
warmstart
5 thermoCOMPACT
Green indicator
(3)
is illuminated
but
has no function
lnitial
checks before turning ON
Open the service valves
.
Ensure
the cold
water
service valve is open. This
can
be
checked by opening a hot water
tap and ensuring
water flows.
.
Ensure that
the service valves in the heating flow
and
return
(2
and
1)
and the
gas
service valve
(3)
are open.
-.-=
The
flow return
and
gas
service valves are open
U
when
the
line
marking has the same direction
as
the
pipe.
.
The
pressure
relief valve
(4)
is
provided
for safety rea-
sons and must not be interfered with.
.
Check the water contents of the system on the
pressu-
re
gauge
(1).
The
needle on
the
pressure gauge
should
be
within
the
green
band
(between
1 and 1.5 bar). lf the needle
displays
a
value
below 0.8 bar
when
the appliance
is
cold,
follow
the instructions
left
by
your
installer
to
refill the
system.
Alternatively,
your
installer should be
called
to
refill
the system.
/-f''€l1
("
\*'€L
r\)
--:!l::r'
rsiei
Fig. 8.3:
Opening service valves
----
Note:
u-J
a
bottom cover is fitted to the
appliance.
The
service valves
can be seen through the cover.
,---=
picture
shows a turboMAX
plus
boilen Check the
u
water contents
Fig.
B.4:
Checking the
water level
Domestic
hot water
operation
(turboMAX
plus
only)
The
boiler should only be used
when
the
heating
system contains waten
Use
of
the
boiler without
water may cause damage to the boiler or its
components.
Setting the maximum
domestic
hot water
temperature
control
.
Turn
the main switch
(2)
to the
,,1"
position.
.
The
display will
show the
boiler flow temperature which
indicates
electrical
power
to the boiler.
.
The domestic hot water
temperature can be adjusted
using the hot water temperature control
(3).
.
Turn
the control clockwise to increase
the temperature
and
anti-clockwise to decrease thetemperature.
As
a
guide
for normal circumstances
set the
knob
to the
one
o'clock
position.
^
Note:
L-f
tnis
control adjusts the
maximum
domestic
hot
water
temperature.
lf
adjusting the control
'
upwards appears
to
have no
effect on the tem-
perature,
then the boiler
is
already operating at
full output for
the
selected flow rate.
lnstructions for
use turboMAX
plus,
thermoCOMPACT
1'