Te**B* *f **mt**ts t G*n*raB E*f*rm*ti*n Key to symbols Table of contents I General information 2 Key to symbols 2 2 2 2 Liability Specified use . . ECdesignation....... Note Almnortant fnis symbol is used to indicate important -.--= u instructions. 3 Factory Guarantee 3 ' This symbol is used to indicate a required step' 3 Liability 4 Operation 4 2 Safety instructions Ov0rview lnitial checks before turning ON . .
*;3#**;_Y :=SeSq,e in*&r* {jLNE{"}€Eb ;iibtE aF.*"i*** *? d Er**t*ny G#*re*t*# # 2 Safety instructions Setup and adjustments lnstallation and adjustment of the boiler as well as service maintenance and repair of the boiler may only be carried out by a competent person in accordance with the Gas Safety (lnstallation and Use) Regulations 1998. (ln the U.K. ,,CORGI" Registered installers undertake the work to a safe and satisfactory standard).
*p*r*tE*n You can identify a thermoCOMPACT boiler by the sticker which is situated at the top left hand side of the control panel (see A, Fig.1.b) 4 Operation Overview turboMAX plus 87 6 Operating controls For access to the controls press the upper middle of the lower front panel and drop it down.
1' . 4 turboMAX plus Green warmstart indicator (3) llluminated = Warmstart switched ON Not illuminated = Warmstart is switched OFF and there is no demand for hot water Flashing = There is either a demand for hot water or warmstart 5 thermoCOMPACT Green indicator (3) is illuminated but has no function lnitial checks before turning Check the water contents of the system on the pressure gauge (1). The needle on the pressure gauge should be within the green band (between 1 and 1.5 bar).
€ *p*r*tE*r: lf you live in a hard water area please do not set the control knob above the mid (12 o-clock) position to prevent excessiv scale formation (fig. 8.5). . . The warmstart system is activated by turning the hot water temperature control knob (1) all the way to the very right for a short time. The green indicator light will now illuminate. Reset the hot water temperature control knob to the desired setting.
F *per*ti*n 4 Heating operation Setting the maximum radiator temperature control . Turn the main switch (1) to the ,,1" position. . Set the maximum radiator temperature control to the desired setting using the control knob (2). We recommend the following settings: - Left setting during spring and autumn, - Middle setting during mild winter, - Riqht setting during cold winter.
4 *p*r*ti*n When a hot water tap (turboMAX plus only) or the central heating system requires heat, the boiler automatically ignites and starts to operate. tf the automatic ignition is not successful within 1O seconds, then the boiler does not go into operation and switches to ,,Lock out". This is indicated visually by the red indicator tight (1) and the displaying of fault code ,,F.28" or ,,F.29" (flame extinguished during operation).
*pen*ti** Turning the boiler OFF Care and maintenance (thermoCOMPACT only) To . 4. turn OFF the central heating Turn the maximum radiator temperature control knob used to control the heating supply temperature (1) all the way to the left. Clean the outer casing of your boiler with a damp cloth and a little soap. Do not use abrasive or solvent cleaning agents that may damage the case or the plastic fittings. The appliance should be serviced at least once per year.
*A d+ us*r**at#81 Troubleshooting Status display ln the unlikely event that a problem occurs with the operation of the turboMAX plus or thermoCoMPACT boiler, the following points should be checked: (For maintenance and service work performed by your installer or service agent) The status displays are activated by pressing the ,,i" button (1). The current status code. e.g. ,,S.34" for the frost protection mode, is shown on the display (2).