PARTS REPLACEMENT
DHW heat exchanger
(TURBOmax Plus only)
Refer to the important information
and initial preparation on page 59.
Release central heating water
pressure.
Remove the diverter valve and
pump as previously described.
Disconnect wire from the NTC.
Remove the spring clips (3 and 4).
Undo the bottom left hand union
(2).
Push the heat exchanger (5)
backwards to disconnect.
Re-assemble in reverse order.
Pressure relief valve
Refer to the important information
and initial preparation on page 59.
Release central heating water
pressure.
Remove the spring clip (5).
Disconnect the discharge pipe from
the pressure relief valve.
Remove pressure relief valve.
Re-assemble in reverse order.
5
1
2
3
4
Fig. E.18: DHW heat exchanger