24
BOILER INSTALLATION SEQUENCE
Cold water mains inlet
and hot water outlet
(TURBOmax Plus)
Flush all foreign matter from the mains
supply before connecting to the
boiler.
Connect the cold water service
valve (1) to the cold inlet water
connection (3) of the appliance
with the washer (2) provided and
tighten.
Connect the 15 mm cold water
inlet pipe copper tail (4) to the cold
water service valve (1) and tighten.
Connect the 15 mm hot water
outlet copper tail (6) to the hot
water outlet connection of the
appliance (8) with the washer
provided (7) and tighten.
Note: The hot water outlet union
nut is packed in with the PRV fitting
pack.
Connect the cold water service
pipe and hot water outlet pipework
to the copper tails.
Euro B/S 045/0GB_Plus
Fig. I.7: Fitting the hot and cold water connections TURBOmax Plus
TURBOmax Plus