7.6 Handing over to the user
h
Note!
When you have finished the installation, attach
the sticker supplied (835593) to the front case
of the appliance in the user’s language.
h
Note!
If fitted to a sealed system.
Set the maximum radiator temperature control to the
desired setting.
Set the maximum hot water temperature control to
the desired setting (If optional Vaillant accessories are
fitted).
Instruct the user in the safe and efficient operation of
the boiler.
Go through the operating manual with the user and
answer any questions.
Show the user how to operate any external controls.
• Explain to the user the importance of having the boiler
regularly serviced by a competent servicing company.
To ensure regular servicing, it is strongly recommended
that arrangements are made for a maintenance agree-
ment. Please contact Vaillant Service Solutions (0870
6060 777) for further details.
If applicable record central heating operating pressure
in the Benchmark gas boiler commissioning checklist
along with the heat input (kW) and temperature differ-
ence between flow and return.
Leave the user instructions and the installation instructions
with the user.
Inform the user that the instruction manuals should
be kept near the appliance.
8 Inspection and maintenance
8.1 Inspection and maintenance intervals
a
Danger!
Risk of injury and risk of damage to property
due to neglected inspection and maintenance!
Neglected inspection and maintenance works or
not observing the stated inspection and main-
tenance intervals can interfere with the opera-
tional safety of the boiler and can result in
damage to property and to persons.
• Point out to the operator that he must ob
serve the demanded inspection and mainte
nance intervals as a minimum.
• Carry out proper regular inspections once a
year.
• Carry out regular maintenance as dictated by
findings during the inspection process The
frequency of maintenance must not be longer
than every 5 years.
a
Danger!
Danger to life and limb due to improper inspec-
tion/maintenance!
Inspections/Maintenance work carried out im-
properly can result in leakages and explosion.
• The boiler may only be inspected/maintained
by a competent person.
All service work must be carried out by a competent
person in accordance with the Gas safety, installation
and use regulations. In the UK this is considered to be a
person approved at the time by the Health and Safety
Executive.
In addition BS 6798: 2009 “Specification for installation
and maintenance of gas-fired boilers of rated input not
exceeding 70 kW net” advises that:
- The person carrying out a combustion measurement
must be assessed as competent in the use of a flue
gas analyser and the interpretation of the results.
- The flue gas analyser used must be one meeting the
requirements of BS7927 or BS-EN50379-3 and be cali-
brated in accordance with the analyser manufactur-
ers’ requirements.
- Competence can be demonstrated by satisfactory
completion of the relevant ACS standard assessment,
which covers the use of electronic portable flue gas
analysers’ in accordance with BS 7967, parts 1 to 4.
- The flue gas analyser is set to the correct fuel setting.
h
Note!
Safe combustion can only be verified by meas-
uring CO/CO
2
ratio. This must not exceed the
value shown in table 9.1.
7 Functional checks commissioning (Part II)
8 Inspection and maintenance