Installation manual
10 Instructions for use ecoTEC
4.5.2 Switching the warmstart function on and off
The warmstart system of the ecoTEC combination boi-
lers provides you with hot water at the required tempe-
rature immediately. To do this, the hot water heat
exchanger of the ecoTEC is kept at a pre-selected tem-
perature level and the boiler will therefore periodically
operate to maintain this temperature.
ecoTEC plus:
b
c
b
a
1
1
Fig. 4.10 Switching the warmstart system on and off with
ecoTEC plus
• Activate the warmstart system by briefly turning the
knob (1) all the way clockwise (position a).
Then select the required temperature, e.g. setting b.
This corresponds to:
- left limit approx. 35 °C
- right limit max. 55 °C.
The water is now kept constantly at this temperature
and is available directly as you turn on a tap. The symbol
flashes in the display.
• Switch off the warmstart system by briefly turning the
knob (1) all the way anti-clockwise (position c). The
symbol
disappears. Then select the required hot
water outlet temperature again, e.g. setting b.
ecoTEC pro:
b
a
b
c
1
12
2
Fig. 4.11 Switching the warmstart system on and off with eco-
TEC pro
• Activate the warmstart system by briefly turning the
knob (1) all the way clockwise (position a). The green
LED (2) lights up.
Then select the required temperature, e.g. setting b.
The water is now kept constantly warm and is available
immediately as you turn on a tap.
• Switch off the warmstart system by briefly turning the
knob (1) all the way anti-clockwise (position c). The
green LED (2) goes out. Then select the required hot
water outlet temperature again, e.g. setting b.
4.5.3 Drawing hot water (ecoTEC combination boilers
only)
1
Fig. 4.12 Drawing off hot water (example: ecoTEC plus)
On opening a hot water tap (1) at a supply point (basin,
shower, bath, etc) the ecoTEC combination boiler will
automatically operate to deliver hot water.
On closing the tap the boiler switches OFF (or continues
to operate for central heating if required).
4 Operation