Technical data
Installation and Servicing ecoTEC plus 35
8 Inspection and maintenance
Fig. 8.6 Fan, Gas valve and Burner
Note!
If the burner has to be removed it will require a
new gasket when refitted.
Note!
When replacing ensure that the sealing
grommet, situated below the gas valve is
correctly re-seated.
8.1.7 Combustion chamber and heat exchanger
Refer to fig 8.8.
Remove loose debris from combustion chamber using
a soft brush and vacuum cleaner. Carefully flush any
remaining debris through the condensate trap (ensure
the water is kept away from electrical components).
Fig. 8.7 Compact thermal module
BURNER
DOOR
SEAL
BURNER
GAS
VALVE
COMPACT
THERMAL
MODULE
INSULATION
FAN
SECTION THROUGH
BURNER DOOR SHOWING
POSITION OF SEAL
GAS VALVE
FAN
COMBUSTION
CHAMBER BURNER
DOOR SECURING
NUTS (5 OFF)
BURNER DOOR
GAS VALVE
GAS PIPE
BRACKET
ELECTRICAL PLUG
IGNITION
ELECTRODE
CONNECTOR
CHASSIS FRONT
RETAINING SLOTS
L
EAD
ELECTRICAL
LEAD
EARTH SPADE
CONNECTOR