Technical data

Installation and Servicing ecoTEC plus22
Fig. 4.8 Mains Supply Connection
Fig. 4.7 Mains Supply Connection
4.4.1 Connection to the main supply
Lower the electronics box, see fig. 4.7.
Opening the electronics box
Unclip the bottom of the electronics box cover and
hinge back to reveal the connection plugs.
Feed the power supply flex into the appliance
and the electronics box through the cable clamps
provided.
4.4.2 Wiring system
Connect the flex to the L, N and earth terminal
block, see fig 4.8.
Green/yellow (earth) wire boiler terminal Earth
sign Blue (neutral) wire boiler terminal N
Brown (live) wire boiler terminal L
Caution!
Do not connect any mains 230V power to the
connections 7-8-9 or BUS (+,-).
Note!
Ensure that the wires are securely fixed in the
terminal block.
Refit the electronics box cover by pushing
into place until it clips back into position.
Raise the electronics box.
Check the electrical installation by carrying out
short circuit, earth continuity and resistance to earth
tests and a check for correct polarity.
4 Boiler installation sequence
UNCLIP
ELECTRONICS BOX
fuse T2E
250 Volts
Pump
connection
Mains supply
connection
987+- 4 53
230V
24VBUS
NL NL
NL
I
X2
X20
9 4 53NLI
Supplied by HeatingSpares247.com