Technical data
Important information 2
Instructions for Use, Installation and Servicing ecoMAX pro 5
2 Introduction
2.1 General Information
Thank you for choosing a Vaillant boiler. The information
given in this booklet will enable you to obtain the best
performance from your boiler.
The Benchmark logbook should be completed by the
installer and/or commissioning engineer and handed to
the user.
Note!
This boiler must be installed and serviced by a
competent person in accordance with the Gas
Safety (Installation and Use) Regulations 1998.
In the UK 'CORGI' registered installers underta-
ke the work to a safe and satisfactory standard.
This boiler is designed to provide central heating from a
fully pumped open-vented or sealed water system with a
fully indirect cylinder.
The central heating water temperature can be adjusted
on the boiler.
Once the controls are set the boiler operates automati-
cally.
A frost protection programme is also included.
Please read these instructions and follow them carefully
for the correct and economical use of your boiler.
2.2 Gas Category
This boiler is factory set for use on Natural Gas (G20).
ecoMAX pro 28E only can be field adjusted for use on
LPG (propane G31), see page 22-23 for instructions.
2.3 Gas Safety (Installation and Use) Regulations
In your own interests and that of safety, it is the Law
that ALL gas appliances are installed by a competent
person in accordance with the current issue of the
above regulations.
2.4 Gas Testing and Certification
The boiler is tested and certificated for safety and per-
formance. It is, therefore, important that no alteration is
made to the boiler.
2.5 CE Mark
This boiler meets the requirements of Statutory
Instrument, No. 3083 The Boiler (Efficiency)
Regulations, and therefore is deemed to meet the requi-
rements of Directive 92/42/EEC on the efficiency requi-
rements for new hot water boilers fired with liquid or
gaseous fuels.
Type test for purposes of Regulation 5 certified by:
Notified body 0086.
Product/production certified by: Notified body 0086.
The CE mark on this appliance shows compliance with:
1. Directive 90/396/EEC on the approximation of the
laws of the Member States relating to appliances bur-
ning gaseous fuels.
2. Directive 73/23/EEC on the harmonisation of the Laws
of the Member States relating to electrical equipment
designed for use within certain voltage limits.
3. Directive 89/336/EEC on the approximation of the
Laws of the Member States relating to electromagnetic
compatibility.
2.6 Control of Substances Hazardous to Health
Under Section 6 of The Health and Safety at Work Act
1974, we are required to provide information on
substances hazardous to health.
The adhesives and sealants used in this appliance are
cured and give no known hazard in this state.
2.6.1 Insulation Pads
These can cause irritation to skin, eyes and the
respiratory tract.
If you have a history of skin complaint you may be sus-
ceptible to irritation. High dust levels are usual only if
the material is broken.
Normal handling should not cause discomfort, but follow
normal good hygiene and wash your hands before
eating, drinking or going to the lavatory.
If you do suffer irritation to the eyes or severe irritation
to the skin seek medical attention.
2.7 Spare Parts
Only original Vaillant spare parts may be used.
2.8 Manual Handling Guidance
During the appliance installation and the replacement of
the heat exchanger it will be necessary to employ
caution and assistance whilst lifting as the appliance or
component exceeds the recommended weight for a one
man lift.
In certain situations it may be required to use a
mechanical handling aid.
Take care to avoid trip hazards, slippery or wet surfaces.
2.9 Warnings
Gas Leak or Fault
If a gas leak or fault exists or is suspected, turn the
boiler mains electrical supply off and turn off the gas
supply at the meter. Consult your local gas company or
your local installation/servicing company.
Clearances
If fixtures are positioned close to the boiler, space must
be left as shown in Fig. 6.1. Enough space must also be
left in front of the boiler to allow for servicing.