Technical data
18
4 Boiler installation sequence
Instructions for installation and servicing ecoMAX18
4.6 Fitting the boiler
• Lift the boiler (3) up to the wall so that it is slightly
above the hanging bracket (1).
Note:
Lift the boiler from either side at the bottom
edge.
• Lower the boiler slowly onto the hanging bracket so
that the cross member at the rear of the boiler fully
engages onto the hanging bracket.
4.7 Removing the front case
Fig. 4.4 Removing/Refitting the case
To remove the front section of the case, 
proceed as follows:
• Loosen the screw (1) on the bottom of the unit.
• Push in the two retaining clips (2) on the bottom of
the appliance until the case is released.
• Grasp the front case (3) by its bottom edge, pull it
towards the front and remove it by lifting it off the
unit.
4.8 Cold water mains inlet and hot water outlet
(ecoMAX 800)
Fig. 4.5 Fitting hot and cold water connections ecoMAX 800
Flush all foreign matter from the mains supply before
connecting to the boiler.
• Connect the cold water service valve (1) to the cold
inlet water connection of the appliance with the 
washer provided and tighten. 
• Connect a 15mm cold water inlet copper pipe (3) to the
cold water service valve (1) and tighten.
• Connect a 15 mm hot water outlet pipe (4) to the 
outlet connection (5) of the appliance.
2
4
2
3
1
5
3
1
2
83 41 77_12 GB04.04.qxd 22.09.2004 12:34 Uhr Seite 18