Installation manual

Installation manual auroTHERM 0020077994_0036
1
Fig. 6.15 Positioning the upper mounting rail
Slide the upper mounting rails towards the
collectors.
Take care that the upper parts (1) of the
clamping elements are over the rails on the
collectors.
Tighten the clamping element with the
socket/combination wrench (13 mm AF).
a
Caution!
After tightening the clamping ele-
ments, make sure the tension is cor-
rect by shaking the upper part of the
clamping element. If it can be moved,
retighten the nut.
Fig. 6.16 Fitting the hydraulic connections
For systems with collector sensors: Plug
the collector sensor into the opening provi-
ded on the flow side of the collector (hot
side).
h
Note
It is possible to attach the collector
sensor to the left or the right side of
the collector array, as the collectors
have a corresponding opening on each
side.
Always ensure the VR11 sensor is fit-
ted to the hot side of the collector
array.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
To prevent damage when tightening
the compression fitting, always use a
second spanner to provide a counter
force.
Connect the collector supply and return to
the system with the connection pipes.
To do this, connect the compression fitting
(from the VTK basic module connecting kit,
Part No. 0020076785) to the collector and
connect this to the connecting pipe.
If necessary check the connections for
leaks.
6 Flat-roof mounting