Installation manual

35Installation manual auroTHERM 0020077994_00
Fig. 6.11 Removing the carrying straps
Remove the carrying straps.
1
Fig. 6.12 Mounting other collectors
Place the next collector on the lower moun-
ting rail at a distance of approx. 10 cm from
the first collector.
1
2
A
B
Fig. 6.13 Joining the collectors
Couple the double nipple (A) (from the VTK
expansion module connecting kit, Part No.
0020076779) to the union nut (B) on the
first collector.
Push the collectors together.
Fig. 6.14 Tightening the compression fitting
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
To prevent damage when tightening
the compression fitting, always use a
second spanner to provide a counter
force.
Tighten the two union nuts on the double
nipple.
Flat-roof mounting 6