Installation manual

34
20
A B
1
1
2
Fig. 6.7 Positioning the mounting rails
If multiple collectors are mounted, have the
mounting rails (1) meet in the centre of the
frames (2) (A).
On the first and last frame, the mounting
rails (1) should project by 20 mm over the
edge (B).
1
Fig. 6.8 Joining the mounting rails
Insert the connecting elements (1) into the
ends of the mounting rails.
Join the mounting rails and fix them to the
frame clamping elements.
Compensate any difference in height by
moving the clamping elements.
1
Fig. 6.9 Hooking the collector
Place the collector with the lower edge in
the section of the mounting rail.
Position the upper part (1) of the clamping
element over the rail on the collector.
Tighten the clamping elements of the lower
mounting rail with the socket/combination
wrench (13 mm AF).
a
Caution!
After tightening the clamping ele-
ments, make sure the tension is cor-
rect by shaking the upper part of the
clamping element. If it can be moved,
retighten the nut.
1
Fig. 6.10 Peeling the film from the edges of the collector
Lift the film at the edges of the collector.
This will facilitate pulling off the film later,
after commissioning.
H
Danger!
Danger of burning!
In case of solar irradiation inside the
units, collectors can reach
300 °C. Remove the sun protection
film installed at the factory only
after the solar energy system has
been started up.
Installation manual auroTHERM 0020077994_00