Installation manual

27Installation manual auroTHERM 0020077994_00
Fig. 5.21 Fitting the hydraulic connections
For systems with collector sensors: Plug
the collector sensor into the opening provi-
ded on the flow side of the collector (hot
side).
With several rows of collectors:
Connect the rows of collectors in accor-
dance with the interconnection schemes
(cf. Section 4.4).
h
Note
In general it is possible to attach the
collector sensor to the left or the
right side of the collector array, as
the collectors have a corresponding
opening on each side.
Ensure VR11 sensors are fitted to the
hot side of the collector array.
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
To prevent damage when tightening
the compression fitting, always use a
second spanner to provide a counter
force.
Connect the collector supply and return to
the system with the connection pipes.
To do this, connect the compression fitting
(from the VTK basic module connecting kit,
Part No. 0020076785) to the collector and
connect this to the connecting pipe.
If necessary check all connections for
leaks.
1
3
2
Fig. 5.22 Insulating the hydraulic connections
After commissioning:
Insulate the hydraulic connections with the
Armeflex insulation (1) (from the VTK ex-
pansion module connecting kit, Part No.
0020076779).
Cover the insulation with the cover clip (2)
(from the VTK expansion module connec-
ting kit, Part No. 0020076779).
Insulate the hydraulic system connections
with the EPDM insulation (3) (from the VTK
expansion module connecting kit, Part No.
0020076779).
On-roof mounting 5
GB