Installation manual

25Installation manual auroTHERM 0020077994_00
1
Fig. 5.15 Mounting other collectors
Place the next collector on the lower
mounting rail.
Make sure that the upper part (1) of the
clamping element is above the collector
rail.
Tighten the lower clamping elements on
the collector.
Slide the upper mounting rails and clam-
ping elements little by little from the top
against the collector.
1
2
A
B
Fig. 5.16 Joining the collectors
Couple the double nipple (A) (from the VTK
expansion module connecting kit, Part No.
0020076779) to the union nut (B) on the
first collector.
Push the collectors together.
Fig. 5.17 Tightening the compression fitting
a
Caution!
Danger of damage to the collector as
a result of incorrect assembly!
To prevent damage when tightening
the compression fitting, always use a
second spanner to provide a counter
force.
Tighten the two union nuts on the double
nipple.
1
Fig. 5.18 Positioning the upper mounting rail
Slide the upper mounting rails towards the
collector.
Take care that the upper parts of the clam-
ping elements are over the rails on the
collectors.
On-roof mounting 5
GB