Installation manual
17Installation manual auroTHERM 0020077994_00
5.1 Fitting the brackets
For collectors arranged side-by-side
• Mount the anchors for the mounting rails at the fol-
lowing distances:
h
Note
During final fixing the pre-assembly dimension
A is reduced by approx. 20 - 25 mm. Take care
that there is adequate clearance on the an-
chors, therefore.
Number of
collectors
A* B C D
VTK 570/2
1
1663 / 1638
50 - 100
507 - 607
707
2 1414
3 2121
4 2828
5 3535
6 4242
7 4949
8 5656
9 6363
10 7070
11 7777
12 8484
13 9191
14 9898
VTK 1140/2
1
100 - 200
997 - 1197
1397
2 2794
3 4191
4 5588
5 6985
6 8382
7 9779
* Pre-assembly dimension / Finished dimension
During final fixing of the collectors, the pre-assembly dimension
is reduced by approx. 20 - 25 mm.
Table 5.1 Spacings when arranging collectors side-by-side
[in mm]
B
B
B
C
B
A
D
A
A
Fig. 5.1 Spacings when arranging collectors side-by-side
On-roof mounting 5
GB