Installation manual

Installation manual auroTHERM 0020077994_0016
4.5 Preparing the hydraulic connection
4.5.1 On-roof mounting
Fig 4.11 Passing the pipe through the sarking membrane
If there is a sarking membrane, proceed as follows:
Make a v-shaped cut in the sarking membrane.
Fold the upper, wider flap on to the roof batten above,
and the lower, narrower flap on to the roof batten
below.
Fix the sarking membrane tight to the roof batten.
This ensures that the dampness flows away to the
side.
With board-clad roofs, cut out a hole with a padsaw.
Work the roofing felt as described for the sarking
membrane.
4.5.2 Flat-roof mounting
a
Caution!
The roof skin can break and cause leaks!
When installing the roof sealing surfaces, make
sure the roof skin is adequately protected.
Place large protection mats under the system.
If the frame is screwed directly, check the sealing of
the building shell.
4.6 Required tools
Have the following tools ready for assembling the
tube collectors.
Fig. 4.12 Assembly tools: spirit level, cordless screwdriver,
Torx bit (TX30, supplied), allen key 5mm,
socket/combination wrench (13 mm), hammer,
measuring tape / folding rule
5 On-roof mounting
With on-roof mounting, the tube collectors are fastened
to horizontal mounting rails quickly and reliably with at-
tachment clips. To ensure a good adaptation to the dif-
ferent roofings, four different brackets are available:
- Type P for standard concrete tiles (e.g. pantile),
- Type S for extremely high protruding tiles (e.g. Medi-
terranean clay tiles)
- Type S flat (low profile) for flat tiles or slate roofs.
- Stair bolt mounting kit for universal fixing (e.g. corru-
gated slabs, sheet with trapezoidal corrugations, shin-
gles).
a
Caution!
Risk of corrosion!
On roofs made of metals more noble than alu-
minium (e.g. on copper roofs) galvanic corrosion
can occur at the anchor points, whereby the at-
tachment of the collectors is no longer guaran-
teed. Ensure that the metals are separated by
suitable underlays.
When mounted on the roof, the Vaillant tube collectors
in the collector array can be arranged side-by-side or
above each other.
In general, the installation steps and instructions de-
scribed in this manual are applicable to all collector
arrangements.
Any different installation steps are clearly pointed out:
For collectors arranged side-by-side
For collectors arranged above each other
When arranging the collectors, take note in each case of
the possible interconnection schemes in Section 4.4.
4 Before installation
5 On-roof mounting