QuickSpecs
System Unit
Dimensions
(H x W x D)
(with bezel)
6.94" x 19.0" x 27.55" (17.6cm x 48.3cm x 70.0cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, DIMMs and
processors installed)
100.0 lb (45.4 kg)
Minimum
(one hard drive, two power
supplies, four DIMMs, and
two processors installed)
66.0 lb (30.0 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 - 127 VAC,
200 - 240 VAC
Rated Input Current
12 A (at 100 VAC),
8 A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
1161 W (at 100 VAC),
1598 W (at 240 VAC)
BTU Rating
Maximum
3960 BTU/hr (at 100 VAC),
5450 BTU/hr (at 200 VAC)
Power Specifications
NOTE:
To review typical system power ratings use the HP Power Advisor
which is available online located at url:
www.hp.com/go/proliant-energy-
efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL580 G7
- Follow the instructions of the next screens.
Power Supply Output
(per
power supply)
Rated Steady-State Power
910 W (low line),
1300 W (high line)
Maximum Peak Power
910 W (low line),
1300 W (high line)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be limited
by the type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP ProLiant DL580 Generation 8 (Gen8)
Technical Specifications
DA - 14743 North America — Version 1 — February 18, 2014
Page 43