Wet/Dry Vacuum Operator’s Manual 12 Gallon Model No. VJH1211PF 0203 FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. Distributed By Cleva North America, Inc. 601 Regent Park Court Greenville, SC 29607 Replacement Filters & Accessories available at: Vacmaster.
TABLE OF CONTENTS SECTION PAGE Warranty........................................................................................................................................... 2 Important Safety Instructions............................................................................................................ 3 Double Insulation Instructions.......................................................................................................... 4 Extension Cords...................................
IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM. Read and understand this operator’s manual and all labels on the vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this vacuum only as described in this manual. To reduce the risk of personal injury or damage to your vacuum, use only manufacturer recommended accessories. SAVE THIS MANUAL FOR FUTURE REFERENCE.
CAUTION: To reduce the risk of injury from moving parts - Unplug before servicing. WARNING: To reduce the risk of electric shock - Unplug before cleaning or servicing. When using as blower: • Direct air discharge only at work area. • Do not use Wet/Dry Vacuum as a sprayer. • Do not direct air at bystanders. • Keep children away when blowing. • Wear safety goggles.
EXTENSION CORDS When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use. Length of Extension Cord 120V 25ft (7.62m) 50ft (15.24m) Ampere rating 100ft (30.48m) 150ft (45.72m) A.W.G.
UNPACKING & CHECKING CARTON CONTENTS A Remove all contents from the box. Remove the power head and take out any contents inside the collection tank. Check each item against the carton contents list. B Carton Contents List: C D F J K O Aspiradoras Mojado/Seco MANUAL DEL USUARIO E G H I L M N Key A B C D E F G H I J K L M N O Description......................................... Qty. Vacuum Assembly.................................. 1 Hose.....................................................
GENERAL ASSEMBLY INSTRUCTIONS A Philips head screw driver is required. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WARNING: DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE SURE THE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VACUUM. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN. UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Undo the latches (Fig. 2). 3.
NOISE DIFFUSER For quiet operation, install the noise diffuser into the blower port by inserting the locking end of the diffuser into the blower port and turning clockwise to lock into place. POLARIZED PLUG To reduce the risk of electrical shock, this appliance has a polarized plug (one blade wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.
not to damage the bag. 5. Place the power head back on the collection tank, aligning the top section with the latches, and lock into place (Fig. 5). OPERATING INSTRUCTIONS: DRY VACUUMING 6. Insert the locking end of the hose into the vacuum port and turn to lock into place (Fig. 6). 7. Choose the desired accessory and insert onto the end of the hose or extension wand (Fig. 7). 8. Verify that the switch is in the 'O' (OFF) position before plugging the power cord into the outlet. 9.
6. Once you have completed vacuuming, flip the on/off switch to the 'O' (OFF) position and unplug the power cord from the outlet. 7. After use, empty the collection tank by unscrewing the drain cap. Drain liquids into a suitable receptacle or drain (Fig. 6). Remember to refit the drain cap to the collection tank. Remove the foam wet filter and allow it to air dry before storage.
MAINTENANCE 1 2 3 4 5 6 7 EMPTYING THE COLLECTION TANK WARNING: ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING THE POWER HEAD FROM COLLECTION TANK. 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Disconnect the hose from the vacuum (Fig. 2). 3. Undo the latches and remove the power head from the collection tank (Fig. 3). Place power head on a soft, clean surface upside down. 4.
INSTALLING & CLEANING CARTRIDGE FILTER 1 2 3 4 5 6 INSTALLING CARTRIDGE FILTER 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Remove the power head and place in an upside down position. 3. Install the cartridge filter over the filter cage making sure the cage is completely covered. Carefully push filter in until it stops against the power head (Fig. 2 & 3). 4.
TROUBLESHOOTING WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE TROUBLESHOOTING. PROBLEM POSSIBLE CAUSE Check the power supply, cord, breakers, and fuses. No power supply. The wet/dry vacuum will not Faulty power cord. operate. Collection tank is full. Switch in the wrong position. The dust comes out from the motor cover. Reduced efficiency and motor/speed vibration. SOLUTION Unplug and check the power cord. If damaged, have it repaired by a professional. Empty the collection tank.
EXPLODED VIEW 14
PARTS LIST Part 1 Drawing Number 551006102 2 Description Quantity Hose Storage Rack 2 Power Head Assembly 1 3 551006103 Float 1 4 551005104 Filter Cage 1 Collection Tank 1 551006107 Vacuum Port Assembly 1 5 6 7 551006106 Vacuum Port Cover 1 8 551002110 Drain Cap Assembly 1 9 551006109 Caster Foot Assembly 4 10 551004104 Filter Retainer 1 11 VCFF Cartridge Filter 1 12 551060104 EVA Hose 1 13 V2EW Extension Wand 2 14 V2FB Floor Nozzle 1 15 V2CT Crevice T