Operating instructions

10 Technical data
60
10.1 Notes for testing institutes
The correct determination of the declaration data is given with wash item
after an intake phase of 5 complete drying programmes (Automatic
programme: Normal drying ).
Wash the base mesh filter in the base cassette after every drying
programme.
The moisture sensor is calibrated based on average water hardness levels.
To adjust the water conductivity value of the appliance according to the
norm (0.45 mmol/l), set the level of dryness to «4» in the user settings.
Set to standard programme according to AS/NZS 2442:
Cotton, normal dry, 6 kg load capacity
Press the button.
10.2 Automatic energy-saving standby
The appliance is equipped with automatic stand-by to avoid consuming
energy unnecessarily.
The appliance door must be kept closed to obtain the lowest standby current
consumption.
All displays go out within minutes of a programme finishing. Energy
consumption is reduced to an absolute minimum. The safety functions,
however, remain activated.