Installation Guide

Installation instructions
«Front loader» washing machine
One-family household
1064373-06
22/10/2021
1064373-06
6
6. Plumbing in
Local water authority regulations must be observed.
Any old water supply and drain hoses must always be replaced with new hoses.
Water inlet
Only cold water G¾” permitted, possible pressure range: 0.1–1.0 MPa (1–10 bar).
The appliance must not be connected to a mixer tap or a continuous flow boiler!
1
A
Preferred alignment for Aquastop valve
blockA (sound-optimized installation):
The tap seal seat must be clean and flat.
Install hose without kinking or twisting it.
Check for leaks.
Water outlet
When installing the drain hose, protect it against damage and kinks!
Installing the drain hose Work steps
Hose clamp
Drain hose A
Rubber connector
ø exterior 28.0 mm
ø interior 21.5 mm
1.5 m
For drainage into fixed upright outflow
pipe, shorten drain hose A to necessary
length.
For drainage into a bath tub or sink, etc.,
drain hose A cannot be shortened!
Drainage into an open-top fixed upright
outflow pipe
Drainage into a bath tub or sink, etc. Work steps
≤1200
≥350
B
A
≤700
A
B
For all connection types, mount the hose
support B near but not to the appliance –
e.g. on a wall or hook.
For drainage into a bath tub or sink, etc.,
secure the hose end with hose support
B.