9. Monitor Parameter Setting
Select Tools ->> Installer Setup(1)/Installer Setup(2), total 8 setting items will be
displayed on screen. Just input the value to modify the setting.
-12-
Item Description
Default
value
User Code
Used to set the monitor code,[1]:master monitor;[2]
the first slave monitor;[3]the second slave
monitor;[4]the third slave monitor;[5] the fouth
slave monitor
1
Language Select
To standard model,support one language only,but
you can customize two languages.
one
Unlock Timing Range from 1~9s
3s
Unlock Auto Off
Range from 0~9s,the monitor will be closed in
setting time after releasing the door.
0
Remote Setup
Used to add the remote controller or delete remote
controller,[0]:delete remote control;[1]:add remote
control.
0
Staircase Light
When the system is connected RLC module
controlling staircase light,the status for staircase
light can be set.[0]: disable at any time when
receive calling;[1]:light on at night only when
receive calling;[2]light on at any time when receive
calling.Note that this item should be set on master
monitor(user code=1),for slave monitors,this item
is invalid.
0(disable)
Online Search... Search the devices connected to the system
_
Recover Settings...
Restore parameter settings to default value,select
Recover Settings
,an information of "Are you sure to
recover all settings" will be asked,press Menu
button to conrm,restore setting will be performed
immediately. Please note that the recover settings
will not change user code item.