VT24 USER MANUAL(EN) 4 Wire Video Intercom System TALK Read this manual carefully before using the product, and keep it well for future use.
-1- 1. Parts and Functions Microphone Mounting Hook JS/PS LCD Screen JS/AP JVD JS/OS1 Up Button Memo Button MENU Button PP+ connection port 1R 2W 3Y 4B 4B 2W 12V UNLOCK Button Down Button Cancel Button TALK Speaker Mounting Hook TALK Button Note 1 Note 2 + = TALK TALK TALK Note:1.Both hands free and handset communication are available. 2.Built-in power supply is optional .
-2- 145~160 cm 2. Monitor Mounting Accessory fittings: 1) Mounting Bracket and special 4 core wire 2) Two screws of 4X25 are used to fasten the Mounting Bracket on the wall. Installation steps: ■ Installation Height for indoor monitor usually is 145- 160CM (refer to sketch map) ■ Attach the screws to the wall to fix the mounting bracket. ■ Refer to the system connection section of this manual, connect wires correctly. ■ Hang the monitor firmly on the bracket. 3.
-3- 4. System Wiring Terminal Discription JSB JS/PS Jumper PP+ 1R 2W 3Y 4B 4B 2W 12V JS/AP JVD JS/OS1 JS/AP JVD JS/OS1 JS/PS 4BS 4BS1 SB_DET CH_DET GD GD 12PS PP+ 1R 2W 3Y 4B 4B 2W 12V 1) JS/PS:Power supply connection port.(for built-in power supply model,this terminal is not included.) 2) JVD:JVD is used for setting the video impedance. If only one monitor is installed, keep the jumper. If multi Monitors are installed, be sure of taking away all JVD of Monitors except the last one.
Red 4 Camera White Black PS 4 User code=2 JVD Removed! TALK 2# Monitor PS 4 4B 2W 12V 1R 2W 3Y 4B PP+ Back View JS/PS JVD Reserved TALK N# Monitor PS User code=N(N<5) AC ~ AC ~ 4B 2W 12V 1R 2W 3Y 4B PP+ Back View Black White Red Black White Red TALK Extending Audio Phone: 4B 2W 12V 1R 2W 3Y 4B PP+ Back View TALK GX-3P 4B 2W +12 INSIDE (90 Degree ROTATE) JS-AP JS-LK 4B 2W 12V 1R 2W 3Y 4B PP+ Back View TALK AC ~ User code=N(N<5) Reserve! JVD Removed! TALK 1
Door station 4 SET-3Y 150R 75R HI SET-3Y VT-BDU JW/VP3 1R 2W 3Y 4B JW/VP2 1R 2W 3Y 4B JW/VP1 1R 2W 3Y 4B JW/OS 1R 2W 3Y 4B VT-BDU TALK JVD Reserved User code=N(N<5) AC ~ TALK JVD Reserved AC ~ JVD Reserved AC ~ User code=2 TALK User code=1 About the BDU instructions ,please refer to BDU user manual for more detail informations.
1# door station 2# door station 3# door station JW_VP DS1 DS2 JW_VP JS/AP JVD JS/OS1 Remove Black DS4 TALK JS/PS Red DS3 Yellow SET JS/AP JVD JS/OS1 Reserve Black VT-MDS JS/PS TALK Red 4# door station 1R 2W 3Y 4B White User code=N(N<5) Yellow User code=1 White CCTV or Door station PP+ White Yellow Red Black 4B 3Y 2W 1R 1R 2W 3Y 4B 4B 3Y 2W 1R PP+ 4B 3Y 2W 1R About the MDS instructions ,please refer to MDS user manual for more detail informations.
-7- 5. Basic Door Release Operation Answering a Door Call 1. Press the CALL button on door station. 2. The monitor rings,and the visitor's image will be seen on screen. Note:the screen turns off after 40 seconds if nobody answers. 3. Press TALK Button on monitor(the LED will transform to red color), you can communicate hands free(if the monitor takes with handset,pick up handset to talk) with the visitor for 90 seconds.After finishing communication,press TALK button again to end the communication.
-8- 6. Intercom Function Intercom function can be initiated by any Monitor when multi monitors are installed. Intercom: Select Intercom item on main menu on any monitor to enter intercom page, see the diagram on right.select one of user,then press Menu button to call.If the selected monitor answers the call,intercom talking is strating.
-9- 7. Public Memory Sharing(Optional) To perform memory sharing function ,the system must connect VT-MEM module. Public memory sharing means that all monitors can view the recorded pictures which is saved in VT-MEM unit.(about VT-MEM module instructions, plaese refer to VT-MEM user manual for more detail information) For each time calling,the system will record one image automatically. To view the recorded pictures,tap Memo button.
-10- Ring Volume and Night Ring Volume Setting You can set a ring volume for day time and night time individually, 06:00 AM~18:00 PM is the day time by default, but the day time can be modified at any time by yourself(refer to Day time setting section for more detail information). Select Tools item on main menu page,then select User Setup->>Call Tone->> Ring Volume or Night Ring Volume to set a appropriate value.if you don't want to be disturbed at night,you can set the night ring volume to 0.
-11- Monitor Time Setting Select Tools item on main menu page,then select User Setup ->>Monitor Time. Modify the value by touching / button to increse/decrese the value,use button to select the setting item. 601 30 Restore to Default Select Tools ->> User Setup->> Restore to default ,a message will be asked to confirm the restore operation. press Menu button to confirm,All settings will be restored to default except Calendar item.
-12- 9. Monitor Parameter Setting Select Tools ->> Installer Setup(1)/Installer Setup(2), total 8 setting items will be displayed on screen. Just input the value to modify the setting. Description Default value User Code Used to set the monitor code,[1]:master monitor;[2] the first slave monitor;[3]the second slave monitor;[4]the third slave monitor;[5] the fouth slave monitor 1 Language Select To standard model,support one language only,but you can customize two languages.
-13- 10. Specification ●● Power Supply: DC16-24V ●● Power Supply for built-in SMPS: AC110~~230V ●● Power Consumption: standby 1.
Note:
The design and specifications can be modified without notice to the user. Right to interpret and copyright of this manual are preserved. Printed In China / 2011.