Manual

1. Parts and Funcons
2. Unit Mounng
3. Specicaon
Power Supply: DC 24V (supplied by PS4-24V or PS5-24V);
Working Temperature: - 5ºC +45ºC;
Dimension: 89(H)×70(W)×45(D)mm;
QSW
DIN Rail Mounting
JS-VP(OUT)
DC SETUP
JS-OS(IN)
VD3
VD2
VD1
1 2 3 4
ONDIP
QSW
POWER
IN-USE
IN-USE:Status indicator,it will light up or blink when receives signal.
POWER:Working indicator,it will light up when plug in power supply.
DC: Power supply input port.
SETUP:DIP switches,refer to table 1 for detail information.
VD1:2P terminal,CCTV camera1 connection port.
VD2:2P terminal,CCTV camera2 connection port.
VD3:2P terminal,CCTV camera3 connection port.
JS-OS:Input port,connect to door station.(if multi door stations are installed,connectd to MDS)
JS-VP:Output port,connect to indoor monitors.