+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Open on the
Unlock Relay mode (default)
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Closed on the
Unlock Relay mode
+
+
-
-
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
-5-
2. External Power Supply Mode
Whentheelectroniclockisover12Vdc,additionalpowersupplyforthelockisneeded.
• Thepowersupplyforthelockmustbelessthan48Vdc1.5A.
• TheJumpermustberemovedwhenusingexternalpowersupply.Thedefaultsettingis
Power-on-to-Unlocktype(Normally open mode),ifusePower-off-to-Unlocktype,
changetheUnlockRelaymodetoNormally closed mode.
• Ifdifferentunlockingtimeisneededtobecongured,changetheUnlock Timingon
doorstation.
C. Connection for Power-to-Unlock type:
D. Connection for Power--off-to-Unlock type: