User guide
5. Door Lock Connections
JP_LK
12V 300mA
Jumper set to 1-2 position
+
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1
2
3
set to Normally open on the
Unlock Relay mode
12V 300mA
Jumper set to 2-3 position
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
set to Normally Closed on the
Unlock Relay mode
JP_LK
1
2
3
-4-
1. Internal Power Supply Mode
Usetheinternalpowertosupplyfortheelectroniclock,sothatthelockcanbeconnected
tothedoorstationdirectly.Notethatthedoorstationcanonlyoutput12Vdcpower,Anyhigh-
powerlockshoulduseexternalpowerconnectionoritmightcausedamagetothedoorstation.
• Theratedpowerofthelockmustbelessthan12Vdc300mAwhenusinginternalpower
supplymode
• TheGNDmustconnecttothenegativeofthelock,andtheCOMconnecttothepositive.
• Jumpersetto1-2positionforPower-on-to-Unlocksafetytype(Normally open mode);
setto2-3positionforPower-off-to-Unlocktype(Normally closed mode).
• Ifdifferentunlockingtimeisneededtobeconfigured,changetheUnlock Timingon
doorstation.
A. Connection for Power-on-to-Unlock type:
B. Connection for Power--off-to-Unlock type: