2 -Wire Intercom System DT591/592 User Manual DT591 DT592 DT-ENG-591/592-V1 100S719
CONTENTS 1.Parts and Functions............................................................................................. 1 2.Terminal Descriptions........................................................................................... 1 3.Specifications....................................................................................................... 2 4.Mounting............................................................................................................... 2 4.
1.Parts and Functions Camera Lens Speaker 176 mm Night View LED Nameplate Call Button Microphone Rainy Cover 90 mm 23 mm Note: DT592 has two call buttons. 2.
•• •• Lock Control Jumper: To select the lock type: see 5.2.1 , 5.2.2 •• •• •• •• •• Main Connect Port: To connect the bus line and the electronic locks. Doorstation Code DIP: Total 4 doorstations can be supported,see 6.1 BUS: Connect to the bus line, no polarity. PL: External lock power input, connect to the power positive(power +). S1+, S2+: Lock power(+) output, to connect 2 locks.
4.2 Mounting With Rainy Cover 1 2 3 1 2 160-165cm 4.3 Placing Name Label ON name label -3- 1 2 Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel.
4.4 Adjusting Camera Angle use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System Wiring and Connections monitor 1 2 ON 5.
5.2 Electric Lock Connection 5.2.1 Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power-on-to-unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). 4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
connect one lock connect two locks Take off the Jumper BUS PL S1 + S2 + Take off the Jumper S- BUS POWER SUPPLY PL S1 + S2 + S- POWER SUPPLY LOCK LOCK LOCK 5.2.3 Unlock parameter setting(set on monitor) Manual Monitor Memory Playback Monitor Album ? About 1.Touch menu page. Intercom H/W : S/W: Local addr: Unlock timing: Video standard: UI-CODE: MCM-VER.: Updated: Multimedia Close User Setup 09/30/2010 Thu.16:41 --- a1.3 V17.11.418.00 ----------- 2.
5.
5.4 Multi Monitors Connection 5.4.
5.4.
6.Setup ON(1) ON = OFF(0) ON = 6.1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured.The switches can be modified either before or after installation. Bit state Descriptions Default setting, ID = 0(00), set to the first Door Station. ON 1 2 ID = 1(10), set to the second Door Station. ON 1 2 ON ID = 2(01), set to the third Door Station. 1 2 ID = 3(11), set to the fourth Door Station. ON 1 2 6.
Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes .
6.
7.Cables Requirements The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach. The farest monitor monitor with two or four monitors monitor monitor DBC/DBC-4 B C When Monitor quantity < 20 Cable Usage A DPS B C Twisted cable 2x0.75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 A When Monitor quantity > 20 Cable Usage A PS5 B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1.
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.