Manual
IP-2 wire system technical guide
DS Description:
1) 1 DMR11/8 + EP24, ID code: 00
2)Press 32 to call Default GL, 31 to call Guard Station 2(192.168.0.253), 30 to call Guard
Station 3(192.168.0.243)
Call Table Setup: A Block -> right Click then select Management -> Select Call Table ->
Select Button Call Table -> Select View & Edit
Edit Button Call Map table:
Index Device Name IP Adress
32 Default GL 192.168.0.254 FFFF
31 Guard Station 2(G3LV) 192.168.0.253
30 Guard Station 3(IP-Agent) 192.168.0.243
Press Write to DevicetodownloadthesetuptoDT-IPC(192.168.0.24)afternished
-96-