Manual

Basic Tools Detail:
Item Description
Factory
set
IDCode
Ifonlyonedoorstationisinstalledinthisbuilding,set
to1;
Ifmultidoorstationsareinstalled,primarydoorstation
mustbesetto1,andotherslavedoorstationsmust
besetfrom2to4.Notethatmax.4doorstationsis
availableinonebuilding
[1]
Single
UnlockTiming
Tosetthetimethathowlongthedoorkeepsopen
whendoorisreleased.Rangefrom01to99seconds.
[05]
5seconds
UnlockOutput
Tosettheunlockmodetomatchthecorresponding
lock.Randfrom0to1
0
CardManage
Tosetthecardlocation.Ifsetto0,thecardissavedin
doorstation.Ifsetto1,thecardissavedinDT-IPC
0
DoorplateMode
Tosetthecallingmode.Ifsetto0,it'stheauto
mode,thatmeansthecallingwillbeactivateddirectly
afterinputting2digitscode.Ifsetto1,it'sthemanual
mode,thatmeansyoushouldpress"#"buttonto
activatethecallingafterinputtingthecode.
[0]
Automode
AudioOptions...
Tosetthetalkingmode.Ifsetto0,handsfreemodeis
activated.Ifsetto1,handsetmodeisactivated.
0
Parameters... Toshowtheparameters,pleaserefertotable2.1
InstallerCode... Tochangedoorstationadministratorcode [66666666]
Default...
Note thisoperationisirreversible.Oncerestore is
activated,allparameterswillreturntofactorydefault
settingexcepttheinformationofaccesscard.
Table2(InstallerSetup):
-7 -