4. Door Lock Connections
1. Internal Power Supply Mode
Use the powerofthesystemtosupply for theelectroniclock,so that the lockcanbe
connectedtothedoorstationdirectly,withoutanadditionalpowersupplyfortheelectroniclock.
Notethatthedoorstationcanonlyoutput12Vdcpower,thereforethekindoflockislimited.
• Theratedpowerofthelockmustbelessthan12Vdc300mAwhenusinginternalpower
supplymode
• TheGNDmustconnecttothenegativeofthelock,andtheCOMconnecttothepositive.
• Jumpersetto1-2positionforPower-to-Unlocksafetytype(Normally open mode);set
to2-3positionforPower-off-to-Unlocktype(Normally closed mode).Notethatthe
unlockrelaymodeissetontheParametertabofDTCONFIGsoftware.
• Ifdifferentunlockingtimeisneededtobeconfigured,theDTCONFIGsoftwarecanbe
usedtochangetheUnlock TimingontheParametertab(seetheprogramsection).
JP_LK
12V 300mA
Jumper set to 1-2 position
+
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1
2
3
set to Normally open on the
Unlock Relay mode on DT-config
software.
A. Connection for Power-to-Unlock type:
12V 300mA
Jumper set to 2-3 position
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
set to Normally Closed on the
Unlock Relay mode on DT-config
software.
JP_LK
1
2
3
B. Connection for Power--off-to-Unlock type: