Owner's manual
Page 68
K5 System Technical Guide
5) Now Set the new room address for the monitor navigation button, and press menu button to
save the setting
Code Number: [1002]
0010: delete remotes
0011: add remote
0020: set as door bell
0021: not door bell
0022: have door station
0023: no door station
0030: out-delay set
0031: in-delay set
0080: room id set
0090: test armed
0093: direct call gl vd on
0094: direct call gl vd o
8008: MM/DD/YYYY
8009: DD/MM/YYYY
8012: 12 hour format
8013: 24 hour format
2412: restore to default
4.3.3§Address§Seng§with§door§staon
Monitor address also can be set via door station. The steps as follows, take IP-MR18 as an example:
Step1: Entry Monitor Program Page
[----]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
[--------]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
=== Monitor Program ===
Old M. code [ - - - - ]
New M. code [ - - - - ]
>Press Call Button of the
monitor
>Input new Code
>Press # to Program
[ Press Call Button ]
Press # key on
door station
Then input 8003 Input the password:
66666666(Default)
Then entry Monitor
Program page
Chapter 4 K5 System Settings