Owner's manual

Page 60
K5 System Technical Guide
LOCK
PS5
1 2 3
654
7 8 9
#0
*
RF CARD
CN1
CN2
CN-LK
J/KMB
JP-LK
Bus
EB+
EB-
N.O
LK+
LK-
+12V
12
3
T/R-
T/R+
IP-MR18
AC
+
-
+
-
To C5-IPC or Distributor
LOCK
Exit Button
Remove the
jumper
POWER
SUPPLY
Note:
1. Please use DC lock and the related DC power supply
2. Remove the JP-LK jumper
3. Set Unlock Output(unlock mode) for diffirent lock types(#8001-3: Unlock Output)
• Power-on-to-unlock type:Unlock Output=0 (by default)
• Power-off-to-unlock type:Unlock Output=1
4.2.2.2§Door§Lock§Controlled§with§External§Power
§§ 4.3§Monitor§Seng
4.3.1§Concept§of§Address
Address codes are the numbers/letters used by residents, visitors and Switchboard operators to
identify the apartments or villas in the installation. Inside the unit/riser each apartment can be
addressed with a 4 digit code(ABCD),of these 4 digits, the rst 2 digits are meant to be the oor
number, while the last 2 digits serves as the monitor code of each oor. There are 2 calling types
when there is cal made to the monitor: Inside call and Outside call.
Chapter 4 K5 System Settings