Owner's manual
Page 44
K5 System Technical Guide
• Parameters(Debug State->1. Installer Setup->7. Parameters)
Three pages are available inside the parameters, press # to switch between different pages
Table 1
Table 2
Item Descriptions Factory Set
1. Monitor Numbs
To set number of monitors that can monitor the door station at
the same time
[2]
2. Monitor Timing To set the maximum monitoring time on door station [15]
3. Monitor & Talk Enble/Disable talk function when monitor is monitoring
[1]
Enable
4. Monitor & unlock Enble/Disable talk function when monitor is monitoring
[1]
Enable
5. Call Wait Time
The time that the door station keeps calling when no answer on
the monitor
[30]
6. Call Talk Time The maximum talking time between door station and monitors [60]
7. Intercom Time The maximum talking time between dierent monitors [90]
8. Call Ring Times How many times the door station ring when it makes a call [0]
9. Use # to call Whether to input # to call after entering the room number [0]
Item Descriptions Factory Set
1. Local IM as GU
To set the monitor coded 0099 as local Switchboard, so when
the user does ”Call Switchboard ” on the monitor, the call will be
transferred to the 0099 monitor
[0]
Not
activated
2. Multi IM Mode To set how multi-monitors in one apartment were coded [0]
3. Room Table Valid
To use the room table to call the monitor when room table is
downloaded to the door station through ST-Cong
[0]
Not
activated
4. Room Table Only To set how the door station calls the monitor
5. Unlock code 2
The second unlock code, valid only when the door station is set
to use common unlock code
None
6. Unlock Code mode To choose to use common unlock mode or private unlock mode
[0]
Common
unlock
mode
7. Code Error Alarm Reserved
8. Code & Card Reserved
9. Code Disable Reserved
Chapter 4 K5 System Settings