Page 31
K5 System Technical Guide
•
PA204:
Reserved in normal status, for door
station communication in test status
•
LED201:
Power indicator
•
LED202:
Reserved
•
LED203:
Picture saving indicator
•
LED204:
Picture play indicator
•
JWP101:
Power input, DC 24V
•
RS485:
PC port. To update the rmware
•
CN-NET:
RJ45 Network Port, connected to
LAN
•
FM-SET:
Video match switch
Specication
• Power supply: DC24V
• Standby current: 78mA
• Working current: 135mA
• Working temperature: -10
0
C~40
0
C
• Connection port: RJ45
• Dimensions: 140*150*60mm
2.3.4.7§Independent§Access§Controller:§GP-ACS
GP-ACS is an independent access controller, used for the entrance without the need for door sta-
tion. Two locks and card readers can be connected to this device, so it can control two entrances
at the same time. GP-ACS can manage cards independently or through the PC in the network.
• Tow doors control ports (card reader port, electric lock port and status test)
• Lock release delay time setting
• Lock type setting
• Work status indicator
Parts and function
s
•
Power:
Power indicator, always ON while working
•
LINK:
Signal indicator, icker means signal is transmitted in the bus line
•
IN-USE:
Status indicator, ON while working
C5-IMC
1
ON DIP
2 3 4 5 6
P-
P+
P-
P+ T/R+
FM-SET
T/R-
S201
PA201 PA202 PA203 PA204
LED201
LED202
LED203
LED204
S201
PA201
PA202 PA204
PA203
LED202 LED203
LED204LED201
JWP101 RS485 CN-NET FM-SET