Owner's manual

Page 31
K5 System Technical Guide
PA204:
Reserved in normal status, for door
station communication in test status
LED201:
Power indicator
LED202:
Reserved
LED203:
Picture saving indicator
LED204:
Picture play indicator
JWP101:
Power input, DC 24V
RS485:
PC port. To update the rmware
CN-NET:
RJ45 Network Port, connected to
LAN
FM-SET:
Video match switch
Specication
Power supply: DC24V
Standby current: 78mA
Working current: 135mA
Working temperature: -10
0
C~40
0
C
Connection port: RJ45
Dimensions: 140*150*60mm
2.3.4.7§Independent§Access§Controller:§GP-ACS
GP-ACS is an independent access controller, used for the entrance without the need for door sta-
tion. Two locks and card readers can be connected to this device, so it can control two entrances
at the same time. GP-ACS can manage cards independently or through the PC in the network.
Tow doors control ports (card reader port, electric lock port and status test)
Lock release delay time setting
Lock type setting
Work status indicator
Parts and function
s
Power:
Power indicator, always ON while working
LINK:
Signal indicator, icker means signal is transmitted in the bus line
IN-USE:
Status indicator, ON while working
C5-IMC
1
ON DIP
2 3 4 5 6
P-
P+
P-
P+ T/R+
FM-SET
T/R-
S201
PA201 PA202 PA203 PA204
LED201
LED202
LED203
LED204
S201
PA201
PA202 PA204
PA203
LED202 LED203
LED204LED201
JWP101 RS485 CN-NET FM-SET