Owner's manual

Page 29
K5 System Technical Guide
station only
JWB (OUT):
Bus Signal Output. RJ45 port includes audio, data & video. It can be connected to
distributor.
CN-MDS:
Bus Signal Input. RJ45 port, connected to MDS only
CN-NET:
RJ45 Network Port, connected to LAN
JP1/JP2/JP3:
Jumper. Removed if C5-MDS connected
SWI:
Distributor Setting. Match different distributor
Specications
Power input: DC 24V
Standby Current: 185mA
Working Current: 250mA
Video Signal: CCIR, 1Vp-p, 75Ω
Audio Signal: 300~3,400 KHz, 0~240 mV
Transmission Mode: TCP/IP
Connection Port: RJ45
Network Interface: Standard Ethernet interface
Working temperature: -10
0
C ~ +40
0
C
Dimension: 140*150*60 mm
2.3.4.5§Mul-Door§staon§Switcher:§C5-MDS
C5-MDS is used when there are more than one door stations in one block. It serves as a door sta-
tion switcher, to separate video and audio signal for each door station
4 door stations can be connected to 1 C5-MDS
Max. 2 pieces of C5-MDS switchers per block
Parts and Functions
POWER:
Power indicator. Always ON while working.
LINK:
Signal indicator. Flicker means signal is transmitted in bus, always ON means communica-
tion ERROR in bus.
IN-USE:
Status Indicator. ON while working.
ERROR:
Error indication. ON when equipment failure.
JWB (OUT):
Output port. RJ45 port, connected to C5-IPC.