Specifications
35
English
4. To perform the next setting, thread the end of the straps as described in Point 7 at Page 22.
5. Pull on the system and grasp with the arm over your shoulder. You should be able to grasp
with the ngertips to the top of the back plate.
AFTER THE DIVE
Cleaning the BC, Check, Storage and Transport:
Correct servicing and maintenance guarantees you many years reliable function of your
SCUBAPRO
®
X-TEK BC.
Keep the following instructions for care:
• Fill the bladder with fresh water and shake so that the water reaches everywhere.
• Keep the bladder upside down and press the exhaust button on the inator so that all the
water can drain.
• Disinfect the inner bladder on a regular basis to prevent bacterial growth.
• Rinse the outer shell thoroughly with fresh water.
• Clean all valves so that possible dirt is removed.
• Place a small amount of silicone on the quick release collar for the power inator
attachement (SCUBAPRO
®
silicone grease).
• Slightly inate the bladder and hang it up for drying. Do not dry or store the bladder in
direct sunlight.
• Dry store the BC slightly inated in a cool dry place, protected from direct sunlight.
Inspection and Service Interval:
For your safety your BC should be inspected and maintained at an Authorized SCUBAPRO
Service Center at least once a year, more often if you dive frequently. Any damage caused due to
failure to properly maintain the BC is not covered by the warranty.