TL-2000 Translinker combines the shortwave UV CL-1000
Crosslinker (specifications above) and the M-20 transillumina-
tor. The transilluminator is built onto the crosslinker cabinet.
On/Off controls for the transilluminator are located on the
crosslinker panel
The transilluminator uses midrange 302nm UV and a
20x20cm filter
TL-2000 Dimensions:
13.7D x 19W x 8.75H in. (348 x 483 x 222mm)
Weight: 36 lb (16.4 kg)
Translinker
An ultraviolet
blocking cover is
included with the
transilluminator.
UVP Crosslinkers assure consistent UV output for many
applications including DNA bonding and UV curing. UV
crosslinking for attaching nucleic acids to a membrane for
example, takes seconds as compared to oven baking. The
crosslinkers utilize a microprocessor to control and measure
the dose of UV radiation.
Preset and manual controls for ultraviolet or time
exposures
Factory presettings deliver 120,000 microjoules or 5
minutes of exposure; maximum UV energy setting of
999,900 microjoules per cm
2
Microprocessor optimizes the use of energy while ensuring
consistent, maximum energy efficiency and output
Large LED display
Window on the door allows viewing of the process yet
blocks the UV radiation
Five 8-watt ultraviolet tubes emit uniform overhead
UV illumination
CX-2000 Dimensions: Exterior: 15D x 17.5W x 9.75H in. (445 x
229 x 381mm); Interior: 11.3D x 11.4W x 3.6H in. (290 x 287 x
91mm)
CL-1000 Crosslinker is an exposure instrument which
uses shortwave UV energy to bond the DNA to a medium.
CL-1000 Dimensions: Exterior: 13.7D x 15.6W x 8.75H in. (248
x 396 x 222mm); Interior: 12D x 10W x 5H in. (305 x 254 x
127mm)
CX-2000 features a pull-out drawer and shortwave UV.
The CX-2000 operates with the same functions as the
CL-1000 microprocessor controls.
Ordering Information
CL-1000 Crosslinker
254nm UV
Replacement Tube
95-0174-01 (115V)
95-0174-02 (230V)
34-0007-01
CL-1000L Crosslinker
365nm UV
Replacement Tube
95-0228-01 (115V)
95-0228-02 (230V)
34-0006-01
CL-1000M Crosslinker
302nm UV
Replacement Tube
95-0230-01 (115V)
95-0230-02 (230V)
34-0042-01
CX-2000 Crosslinker
254nm UV
Replacement Tube
95-0339-01 (115V)
95-0339-02 (230V)
34-0007-01
TL-2000 Translinker
254nm Crosslinker/
302nm Transilluminator with
Filter Size of 20x20cm
Replacement Tube, 254nm
Replacement Tube, 302nm
95-0300-01 (115V)
95-0300-02 (230V)
34-0007-01
34-0042-01
UV Crosslinkers
TL-2000 Translinker
UV CROSSLINKERS AND TRANSLINKER
U
U
UU
V
V
VV
I
I
II
n
n
nn
t
t
tt
e
e
ee
n
n
nn
s
s
ss
i
i
ii
t
t
tt
y
y
yy
M
M
MM
e
e
ee
t
t
tt
e
e
ee
r
r
rr
s
s
ss
Digital UVX Radiometer is used with one of the three interchangeable
sensors for measuring shortwave (254nm), longwave (365nm) and
midrange (302nm) UV wavelengths.
Choose from three sensors: UVX-25 shortwave, UVX-32
midrange or UVX-36 longwave
The UVX range switch provides
selection from three intensity ranges:
n 0 to 20 mW/cm
2
n
0 to 2000 mW/cm
2
n
0 to 200 mW/cm
2
The attenuator extends the reading range
up to 200mW/cm
2
The UVX Radiometer is powered by a 9-volt battery
for up to 120 hours
A port for a chart recorder allows continuous monitoring
Dimensions: 6.2L x 2H x 3.6W in. (157 x 51 x 91 mm)
Sensor Cable Length: 3 feet (0.9 m)
Weight: 9.4 oz (0.3 kg)
Display: 3.5 digit LCD
Operating Environment: Temperature: 0 to 50
o
C
Humidity: 5% to 90% Relative Humidity
The measurement of the UV irradiance is the most effective way to
monitor the useful life of any UV light source. UVP meters ensure
maximum operating efficiency of any UV system.
J-Series meters are photovoltaic devices for accurate and
repeatable readings of shortwave and longwave UV sources.
The durable plastic housing withstands heavy, sustained use.
A three foot (0.9m) cord connects the sensor to the meter
for remote readings
Infrared filter assures accurate readings when measuring
light sources producing infrared radiation
The 5X attenuation screen can be used for very high
intensity lamp measurements
All meters and sensors are calibrated to meet UVP’s
published standards and NIST
J-221 Meter measures the intensity of 365nm longwave
UV. The sensor is sensitive within a range of 300-400nm
with a peak sensitivity at 365nm. Intensity readings are
0-1200 mW/cm
2
(A Scale) and 1000-6000 mW/cm
2
(B Scale). J-221 Meter complies with MIL STD 45662-A
J-225 Meter measures the intensity of 254nm shortwave
UV. The sensor is sensitive within a range of 220-280nm
with peak sensitivity at 254nm. Intensity readings at
0-2400 mW/cm
2
(A scale) and 2000-12000 mW/cm
2
(B Scale)
Dimensions:
3H x 3D x 3W in. (76 x 76 x 76 mm)
Weight: 9 oz (0.25 kg)
J-221 and J-225 UV Meters measure UV sources
Ordering Information
J-221 Longwave Meter 365nm UV 97-0003-01
J-225 Shortwave Meter 254nm UV 97-0004-01
Ordering Information
UVX Radiometer 97-0015-02
Attenuator, 10:1 98-0035-01
9V Battery 45-0012-01
UVX-25 Sensor
Calibration Point: 254nm
Bandpass: 250-290nm
97-0016-01
UVX-31 Sensor
Calibration Point: 310nm
Bandpass: 280-340nm
97-0016-04
UVX-36 Sensor
Calibration Point: 365nm
Bandpass: 335-380nm
97-0016-02
UVX Radiometer Select from three
UV sensors.
Recalibration
of meters/
sensors is
recommended
every six
months.
Self-powered for maximum portability
Two scales for low and high intensity readings
UV INTENSITY METERS
UVX Digital Radiometers
J-Series Analog UV Meters
14
23